Evidence map›Paper›PMID 42135595›Full record

ArticleMedical physics2026

Uncertainty-aware gamma interaction localization and reconstruction in PET.

Julian Thull, Jan Remennik, David Schug, Bjoern Weissler, Yannick Kuhl, Volkmar Schulz

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Julian ThullDepartment of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Jan RemennikDepartment of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
David SchugDepartment of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Bjoern WeisslerDepartment of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Yannick KuhlDepartment of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.
Volkmar SchulzDepartment of Physics of Molecular Imaging Systems, RWTH Aachen University, Aachen, Germany.

Funding

German Federal Ministry of Research, Technology and Space via NHR4CESNvidia Grant Program
6 · The paper itself

Abstract

backgroundPrecise localization of gamma-ray interactions inside scintillation detectors is essential for high-resolution positron emission tomography (PET) imaging. Although machine learning methods have demonstrated strong performance in gamma interaction positioning, most existing approaches do not quantify event-level uncertainty, leaving valuable information unused. PURPOSE: This study quantifies event-wise positional uncertainties in gamma interaction localization and demonstrates its utility for improving PET image quality through uncertainty-aware filtering and weighting.

methodsWe employ machine learning to perform gamma interaction positioning in a semi-monolithic scintillation detector block with overall dimensions of

resultsAcross architectures, uncertainty-aware models achieved high positioning accuracy. CNN classifiers provided the best planar performance, while CNN regressors performed best for depth-of-interaction (DOI) estimation. Variance- and energy-based filtering substantially improved positioning accuracy, reducing the MAE to

conclusionsEvent-level uncertainty estimation enables meaningful filtering and weighting strategies that improve interaction positioning and reconstructed PET image quality. Despite the trade-off between enhanced spatial resolution and increased noise, the uncertainty-aware framework introduces a new reconstruction parameter that can be exploited to improve image quality and potentially support more reliable quantitative PET imaging.

Indexed as

Gamma RaysImage Processing, Computer-AssistedPositron-Emission TomographyMachine LearningUncertaintygamma positioning calibrationPET image reconstructionuncertainty quantification

Identifiers

PMID42135595
PMCPMC13176420

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.