Evidence map›Paper›PMID 42135269›Full record

ArticleJournal of applied clinical medical physics2026

Investigating the impact of key algorithm parameters and patient-specific factors on the accuracy of CT ventilation imaging.

Jeremy Lim, John Kipritidis, Jeremy T Booth, Paul J Keall, Hilary L Byrne

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Jeremy LimImage X Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.ORCID https://orcid.org/0000-0001-7692-7767
John KipritidisNorthern Sydney Cancer Centre, Royal North Shore Hospital, St Leonards, Australia.
Jeremy T BoothNorthern Sydney Cancer Centre, Royal North Shore Hospital, St Leonards, Australia.ORCID https://orcid.org/0000-0003-4004-1109
Paul J KeallImage X Institute, Faculty of Medicine and Health, The University of Sydney, Sydney, Australia.
Hilary L ByrneFaculty of Medicine and Health, The University of Sydney, Sydney, Australia.ORCID https://orcid.org/0000-0001-7023-7976

Funding

Cancer Institute NSW Translational Program Grant 2019 TPG2165
6 · The paper itself

Abstract

backgroundComputed Tomography Ventilation Imaging (CTVI) is an investigational technique that has its basis in functional lung avoidance radiotherapy. It offers a cost-effective and accessible alternative to nuclear medicine imaging by generating lung ventilation maps from 4DCT or paired inhale/exhale breath-hold CT (BHCT) scans. Despite over a decade of clinical validation, there is still no consensus on how algorithm parameters and patient-specific factors influence CTVI accuracy. Further research is needed to understand CTVI's sensitivity to these variables and to standardize its implementation for clinical use. PURPOSE: This study evaluates how key algorithm parameters and patient-specific factors affect the accuracy of CTVI. MATERIALS AND

methodsCT ventilation images were generated from BHCT scans and compared to Galligas PET ventilation scans. The VESPIR toolkit was used to compute ventilation based on deformable image registration (DIR) evaluation of volume change (CTVI

resultsThe correlation between CTVI and Galligas PET was demonstrated to be robust within identified parameter ranges: lung segmentation threshold -600 HU to -150 HU for CTVI

conclusionsCTVI accuracy was relatively stable across the range of parameter values tested with no strong indication of the need for patient-specific parameter sets. Patient-specific differences appear to be a driving factor for inter-patient variability in CTVI accuracy as parameter selection alone was insufficient to explain the variability. The strong association of CTVI

Indexed as

AlgorithmsFour-Dimensional Computed TomographyImage Processing, Computer-AssistedLung NeoplasmsRadiotherapy Planning, Computer-AssistedTomography, X-Ray ComputedHumansRadiotherapy DosageRadiotherapy, Intensity-Modulatedalgorithm parametersCT ventilation imagingsensitivity analysis

Identifiers

PMID42135269
PMCPMC13175925

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.