Torsional Stability of the Femoral Neck System for Pauwels Type III Femoral Neck Fracture Fixation: A Finite-element Analysis.
Article in Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionFemoral neck fracture fixation remains challenging, particularly for Pauwels type III fractures that require robust implants to withstand vertical shear forces. The femoral neck system (FNS) offers greater stiffness and more stable load sharing than multiple screw fixation; however, it has a lower load-to-failure than plate systems. We evaluated the torsional stability of the FNS using finite-element analysis.
methodsWe analyzed a transcervical Pauwels type III femoral neck fracture without a fracture gap, fixed with one of three constructs: multiple screw fixation, a dynamic hip screw (DHS) with an antirotation screw, or an FNS. Finite-element simulations incorporated muscle forces during the leg-swing phase, with constraints applied at the fovea capitis. Cortical-cancellous interfaces were fully bonded, except at the reduced fracture interface where relative translation was allowed.
resultsThe DHS with an antirotation screw had the highest equivalent von Mises stress and strain energy density (SED) (1130.11 MPa/1,000) and the greatest fragment displacement (0.44 mm). Multiple screw fixation produced the lowest SED (151.73 MPa/1,000), and the FNS showed similar displacement with an intermediate SED (201.96 MPa/1,000). In the FNS, peak stress localized near the lateral cortex of the proximal femur, with reduced stress at the barrel-screw interface.
conclusionsThe FNS provides rotational stability for Pauwels type III fractures comparable with multiple screw fixation and reduces stress at the fracture site. The DHS with an antirotation screw was less stable during hip rotation. Given its greater compressive strength than multiple screw fixation, the FNS is the preferred fixation option.