Evidence map›Paper›PMID 42133459›Full record

ArticleThe Journal of the Acoustical Society of America2026

Increasing ultrasound field-of-view with reduced element count arrays containing large elements.

Mick Gardner, Rita J Miller, Michael L Oelze

Abstract read
PubMed Publisher
In one paragraph

Article in The Journal of the Acoustical Society of America, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Mick GardnerElectrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois 61801, USA.ORCID 0009-0001-0004-0083
Rita J MillerElectrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois 61801, USA.ORCID 0009-0006-6477-4744
Michael L OelzeElectrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, Illinois 61801, USA.ORCID 0000-0002-3099-7425

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Several applications of medical ultrasound can benefit from a larger field of view (FOV). This study is aimed at increasing the FOV of linear array probes by increasing the element width. Coupled elements were used to imitate a larger element width. Through Fourier analysis, theoretical pressure amplitudes, and bandwidth estimates, coupled elements are shown to be close approximations of large elements. The effects of coupling on resolution, contrast, and speckle signal-to-noise ratio are investigated through phantom images and in vivo images of a rabbit tumor reconstructed with plane wave compounding. Furthermore, a positioning system was used to acquire data from a virtual large aperture with 120 mm FOV and 128 elements, collected in sections with a single probe. The null subtraction imaging (NSI), sign coherence factor, and minimum variance (MV) beamformers are compared for regaining resolution lost by an increased F-number. The NSI beamformer decreased full-width at half-max estimates of wire targets by 79% with coupling by 2 compared to uncoupled DAS. The MV beamformer was best for maintaining speckle statistics while improving resolution. Our results demonstrate how increased element width can increase FOV with no increase to element count.

Identifiers

PMID42133459

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked