Evidence map›Paper›PMID 42131871›Full record

ArticleJournal of the Saudi Heart Association2026

Quantifying Patient Positioning Errors and Radiation Dose Variation in Cardiac Computed Tomography Angiography.

Yasser H Hadi, Hassan B Hawsawi, Niamh Moore, Helle Precht, Andrew England, Mark McEntee

Abstract read
In one paragraph

Article in Journal of the Saudi Heart Association, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Yasser H HadiDiscipline of Medical Imaging and Radiation Therapy, School of Medicine and Health, University College Cork, Cork, Ireland.
Hassan B HawsawiDepartment of Medical Physics, King Abdullah Medical City (KAMC), Makkah, Saudi Arabia.
Niamh MooreDiscipline of Medical Imaging and Radiation Therapy, School of Medicine and Health, University College Cork, Cork, Ireland.
Helle PrechtDiscipline of Medical Imaging and Radiation Therapy, School of Medicine and Health, University College Cork, Cork, Ireland.
Andrew EnglandDiscipline of Medical Imaging and Radiation Therapy, School of Medicine and Health, University College Cork, Cork, Ireland.
Mark McEnteeDiscipline of Medical Imaging and Radiation Therapy, School of Medicine and Health, University College Cork, Cork, Ireland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Accurate patient centring at the computed tomography (CT) scanner isocentre is essential for optimising radiation dose. This study aimed to quantify positioning errors, assess their relationship with radiation dose, and estimate the potential dose reduction achievable with optimal centring. Methods: This retrospective observational study included adult patients (≥18 years) who underwent electrocardiography (ECG)-gated cardiac CT angiography between January 2023 and July 2025 at a tertiary hospital. Scans were performed using Siemens SOMATOM Force dual-source CT systems. Vertical and lateral deviations from the scanner isocentre were calculated from scout images using integrated analytics within the institutional dose monitoring platform (Qaelum NV, Leuven, Belgium). Radiation dose indices, including the volume-weighted CT dose index (CTDI Results: Data from 399 patients were evaluated. Significant off-centring (>10 mm) occurred in 83% of scans in the anteroposterior (AP) direction and 50% laterally. Severe AP off-centring (>30 mm) was present in 39% of cases. Off-centring showed no independent association with CTDI Conclusion: Patient off-centring was highly prevalent in cardiac CT examinations. No independent association between off-centring and radiation dose was observed when adjusting for BMI, age, and sex. Literature-based scenario modelling suggests that meaningful radiation dose reductions may be achievable with optimum centring, although this requires prospective confirmation.

Indexed as

Cardiac CTCTOff-centringPatient positioningRadiation dose

Identifiers

PMID42131871
PMCPMC13166806

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.