ArticleJournal of applied clinical medical physics2026

Beam-axis stability during gantry rotation measured with scintillation dosimetry.

Shingo Ohira, Takeshi Ohta, Honoka Sugaya, Tenyoh Suzuki, Yuki Nozawa, Masanari Minamitani, Atsuto Katano, Takuya Hayashi, Hideomi Yamashita, Keiichi Nakagawa

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Shingo OhiraDepartment of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa-ku, Tokyo, Japan.
Takeshi OhtaDepartment of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.ORCID https://orcid.org/0000-0001-8164-8981
Honoka SugayaDepartment of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa-ku, Tokyo, Japan.
Tenyoh SuzukiDepartment of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, Arakawa-ku, Tokyo, Japan.ORCID https://orcid.org/0009-0006-2258-3130
Yuki NozawaDepartment of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.
Masanari MinamitaniDepartment of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.
Atsuto KatanoDepartment of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.
Takuya HayashiDepartment of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.ORCID https://orcid.org/0009-0007-6675-5245
Hideomi YamashitaDepartment of Radiology, The University of Tokyo Hospital, Bunkyo-ku, Tokyo, Japan.
Keiichi NakagawaDepartment of Comprehensive Radiation Oncology, Graduate School of Medicine, The University of Tokyo, Bunkyo-ku, Tokyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVolumetric modulated arc therapy (VMAT) requires high mechanical precision due to continuous gantry rotation. This study aims to investigate beam-axis stability during VMAT delivery and evaluate scintillation-based imaging as a complementary quality assurance (QA) tool.

methodsBeam-axis deviations were measured using a scintillation plate dosimeter, acquiring images at 5 frames per second in axial and coronal planes. Nine conformal arc beams with a field size of 1 × 1 cm

resultsShort-term reproducibility showed maximum standard deviations (SDs) of 0.05, 0.06, and 0.11 mm for 4 MV, 6 MV, and 6 FFF beams, respectively. Long-term reproducibility exhibited maximum SDs of 0.15, 0.13, and 0.19 mm, respectively. Angle-dependent variations were most prominent at gantry angles of 0° and ±180°, consistent with gantry sag under gravity. The 3D displacements between the radiation dose center and the beam axis remained below 1 mm across all energies: the average (maximum) displacement ranged from 0.47 mm (0.96 mm) to 0.52 mm (0.97 mm) for 4 MV, 0.41 mm (0.68 mm) to 0.44 mm (0.76 mm) for 6 MV, and 0.42 mm (0.88 mm) to 0.47 mm (0.95 mm) for 6FFF. No relevant differences were observed among the three EPID/XVI configurations, indicating that these devices have a minimal impact on gantry mechanical stability.

conclusionsScintillation-based imaging enables real-time, high-resolution evaluation of beam-axis stability during VMAT. Deviations were consistently within submillimeter accuracy, supporting its use as a complementary QA method to conventional tests.

Indexed as

Particle AcceleratorsPhantoms, ImagingQuality Assurance, Health CareRadiometryRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedScintillation CountingHumansRadiotherapy DosageReproducibility of ResultsRotationbeam‐axisscintillationstability

Identifiers

PMID42130293
PMCPMC13172761

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.