ArticlePLOS digital health2026
Using wearable sensors during the timed up and go and 6-minute walk test in Spinal Bulbar Muscular Atrophy.
Article in PLOS digital health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Spinal Bulbar Muscular Atrophy (SBMA) is a rare and slowly progressive disease that affects males. The Timed Up and Go (TUG) and 6-minute walk test (6MWT) are used in the clinic to track progression. Recent studies have used wearable sensors to track subtle changes in gait and balance in people with rare disease. The objective of this study was to determine whether inertial sensors could be used in men with SBMA to track changes in gait and balance. Our methods included ten participants with SBMA who completed the TUG and 6MWT while wearing six wearable sensors at the baseline, 6-month, and 12-month follow up visits. Our findings showed that this group of men did not progress in their disease over 12 months as evidenced by the stability of TUG durations, 6MWT distance, and sensor parameters. We observed strong associations between the sensor-derived parameters and both TUG duration and 6MWT distance. The sensors can be used during clinic assessments to measure gait and balance parameters. Further studies examining a larger sample size and at-home monitoring should be considered.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.