Evidence map›Paper›PMID 42126545›Full record

ArticleNeuroradiology2026

Sine spin flat-detector CT for enhanced brain parenchyma visualization: an intraindividual comparison on a latest-generation angiography system.

Marvin Heinrich, Christoph M Mooshage, Michael O Breckwoldt, Fabian Preisner, Kianush Karimian-Jazi, Daniel Schwarz, Alexander Hubert, Tim Hilgenfeld, Christian Herweh, Lena Wucherpfennig and 4 more

Abstract read
PubMed Publisher
In one paragraph

Article in Neuroradiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Marvin HeinrichDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Christoph M MooshageDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Michael O BreckwoldtDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Fabian PreisnerDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Kianush Karimian-JaziDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Daniel SchwarzDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Alexander HubertDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Tim HilgenfeldDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Christian HerwehDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Lena WucherpfennigDepartment of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany.
Martin BendszusDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Dominik F VollherbstDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Markus A MöhlenbruchDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany.
Niclas SchmittDepartment of Neuroradiology, University Hospital Heidelberg, Heidelberg, Germany. niclas.schmitt@med.uni-heidelberg.de.ORCID http://orcid.org/0000-0003-2509-5459

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFlat-detector computed tomography (FDCT) is increasingly used for periinterventional cerebral imaging. The recently introduced Sine Spin FDCT (S-FDCT) aims to improve cerebral soft tissue contrast compared with conventional FDCT (C-FDCT). Reliable visualization of healthy brain parenchyma is essential for detecting pathological changes. This study compared gray-white matter differentiation between intraindividually acquired S-FDCT and C-FDCT.

methodsA retrospective analysis of a prospectively maintained database included patients with ischemic stroke treated by mechanical thrombectomy who underwent both S-FDCT and C-FDCT within the same interventional session on a latest-generation angiography system. Quantitative image quality was assessed using the contrast-to-noise ratio (CNR). Qualitative image quality was evaluated using a five-point scale at basal ganglia and supratentorial cortex. Analyses focused on healthy brain parenchyma contralateral to infarction. Radiation dose was assessed using entrance-skin dose and dose-area product (DAP).

resultsForty patients (74.2 ± 15.3 years) were analyzed. S-FDCT demonstrated a higher CNR than C-FDCT (mean CNR ± SD: 2.62 ± 1.36 versus 1.03 ± 0.38; p < 0.001). Qualitative ratings were higher for S-FDCT at the basal ganglia (2.45 ± 0.71 versus 1.54 ± 0.53; p < 0.001) and supratentorial cortex (3.01 ± 0.80 versus 1.71 ± 0.60; p < 0.001). Inter-reader agreement was good (κ = 0.798). S-FDCT showed a moderately higher radiation dose than C-FDCT (DAP: 50.6 ± 3.10 versus 46.89 ± 2.86 Gy·cm², p < 0.001).

conclusionS-FDCT improves cerebral soft tissue visualization compared with C-FDCT in periinterventional imaging. These findings highlight the potential of Sine Spin technology to enhance FDCT image quality and support its role in advanced angiography-suite-based neuroimaging.

Indexed as

Angiography suiteCerebral imagingFlat-detector computed tomographySine spin FDCTStroke

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.