Microleakage and Torque Loss at the Implant-Abutment Interface in Original Versus Non-Original Abutments: An In Vitro Study.

Ferran Sánchez-Benito, Enrique Castells-Mira, María Cosin-Villanueva, Francisco Gil-Loscos, Andrés López-Roldán

Abstract read
In one paragraph

Article in Materials (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ferran Sánchez-BenitoDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0009-0001-4630-1293
Enrique Castells-MiraDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0009-0007-1701-4774
María Cosin-VillanuevaDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0009-0009-2900-3786
Francisco Gil-LoscosDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.
Andrés López-RoldánDepartment of Stomatology, Faculty of Medicine and Dentistry, University of Valencia, 46010 Valencia, Spain.ORCID 0000-0002-9335-5948

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Microleakage at the implant-abutment interface represents a potential pathway for bacterial penetration and may contribute to peri-implant inflammation, marginal bone loss, and mechanical complications such as screw loosening. The increasing clinical use of compatible prosthetic abutments as cost-effective alternatives to original components has raised concerns regarding their fit, sealing capacity, and mechanical stability at this interface. The aim of this in vitro study was to evaluate differences in sealing capacity and torque loss between original and non-original abutments in a mixed internal connection implant system and to investigate the applicability of a novel quantitative approach for assessing microleakage based on a hydraulic conductance perfusion system. Nine abutments, including four multi-unit and five screw-retained cementable abutments, were connected to Straumann Bone Level implants at two tightening torques (5 N·cm and 35 N·cm). Microleakage was quantified by measuring fluid transport across the implant-abutment interface using the perfusion system, and removal torque values were recorded after testing. Non-original abutments exhibited significantly greater microleakage than original abutments at both torque levels. Microleakage increased significantly when the installation torque was reduced to 5 N·cm. At the manufacturer-recommended torque, screw-retained cementable abutments demonstrated higher microleakage than multi-unit abutments. Non-original abutments also showed significantly greater torque loss. These findings suggest that original abutments provide improved sealing capacity and mechanical stability at the implant-abutment interface, while the hydraulic conductance perfusion system represents a promising quantitative tool for investigating microleakage.

Indexed as

dental implantshydraulic conductanceimplant–abutment interfacemicroleakageprosthetic abutmentstorque loss

Identifiers

PMID42124290
PMCPMC13164815