Evidence map›Paper›PMID 42122637›Full record

ArticleSensors (Basel, Switzerland)2026

Online Monitoring of Transformer Winding Faults Based on Pulse Coupling Injection.

Zetong Wang, Yuhan Zou, Junhao Ma, Zongnan Liu, Xinyu Peng, Tianran Zhang, Sizhe Xiang, Chenguo Yao, Shoulong Dong

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Zetong WangState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Yuhan ZouState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Junhao MaState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Zongnan LiuState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Xinyu PengState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Tianran ZhangState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Sizhe XiangState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Chenguo YaoState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.
Shoulong DongState Key Laboratory of Power Transmission Equipment Technology, Chongqing University, Chongqing 400044, China.ORCID 0000-0001-6104-0282

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aiming at the problems with traditional transformer winding deformation detection, requiring power outages, low signal-to-noise ratios for online monitoring, and insufficient feature extraction, this paper proposes a live monitoring and intelligent diagnosis method based on pulse-coupled injection. At the hardware level, a semi-ring capacitive coupling sensor is developed and designed, which realizes non-contact injection of high-frequency pulse signals and high-SNR extraction without a power outage. The reliability of the system under complex working conditions is verified by field experiments on multiple actual 110 kV transformers. At the algorithm level, an innovative MSCNN-Transformer-PGA deep composite model fused with prior electromagnetic physical knowledge is constructed and combined with the transformer equivalent circuit model. The model uses a multi-scale convolution to extract local details of frequency response signals, adopts Transformer to establish the global sequence dependence, and introduces a Physics-Guided Attention mechanism (PGA) to adaptively focus on the key fault physical frequency bands. The experimental results show that the proposed method effectively overcomes electromagnetic noise interference, and the fault classification accuracy of single-modal pulse frequency response data reaches 97.6%, providing a high-precision online monitoring solution for the safe operation and maintenance of transformers.

Indexed as

capacitive coupling sensorlive monitoringMSCNN–Transformer–PGA modelpulse frequency response methodtransformer winding fault

Identifiers

PMID42122637
PMCPMC13165908

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.