Evidence map›Paper›PMID 42122568›Full record

ArticleSensors (Basel, Switzerland)2026

A Comparative Study of Signal Representations Methods and Deep Learning Architectures for PPG-Based Cuffless Blood Pressure Estimation.

Han Zhang, Xudong Hu, Xizhuang Zhang, Zhencheng Chen, Yongbo Liang, Gang Wang

Abstract readComparative Study
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Han ZhangSchool of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 611731, China.
Xudong HuSchool of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.
Xizhuang ZhangSchool of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.
Zhencheng ChenSchool of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.
Yongbo LiangSchool of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China.ORCID 0000-0002-8337-6147
Gang WangThe Key Laboratory of Biomedical Information Engineering of Ministry of Education, Institute of Health and Rehabilitation Science, School of Life Science and Technology, Xi'an Jiaotong University, Xi'an 710049, China.

Funding

Guangxi Key Research and Development Program Project GuikeFN2600640136National Natural Science Foundation of China 62361013Science and Technology Department of Sichuan Province 2025ZNSFSC0457
6 · The paper itself

Abstract

Hypertension is a major risk factor for cardiovascular disease and requires effective long-term monitoring. Photoplethysmography (PPG), acquired from wearable optical sensors, offers a convenient and non-invasive signal source for cuffless blood pressure (BP) estimation, but existing studies have mainly emphasized model architecture optimization, with limited systematic investigation of signal representation. This study systematically compares seven one-dimensional-to-two-dimensional signal transformation methods and evaluates multiple architectural variants for PPG-based cuffless BP estimation under a unified framework. Experiments were conducted using PPG and arterial BP signals from the UCI Open Blood Pressure Database. The best-performing configuration, based on continuous wavelet transform (CWT), achieved estimation errors of 3.80 ± 5.02 mmHg for systolic BP and 1.65 ± 2.70 mmHg for diastolic BP. Further real-world validation on 26 participants using an Omron cuff-based monitor as the reference showed good consistency, with correlation coefficients of R = 0.96 for SBP and R = 0.74 for DBP. The results demonstrate that appropriate signal representation, particularly CWT, plays a critical role in improving estimation accuracy and robustness, and may facilitate the development of wearable cuffless BP monitoring systems.

Indexed as

Blood PressureBlood Pressure DeterminationDeep LearningPhotoplethysmographySignal Processing, Computer-AssistedAlgorithmsHumansHypertensionWavelet AnalysisWearable Electronic Devicesblood pressure predictiondeep learningintelligent medicinephotoplethysmography (PPG)

Identifiers

PMID42122568
PMCPMC13166007

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.