Evidence map›Paper›PMID 42122435›Full record

ArticleSensors (Basel, Switzerland)2026

A Precise Focusing Simulation Platform for Transcranial Acoustoelectric Brain Imaging.

Jiande Guo, Juan Huang, Xizi Song, Chenghao Hu, Xiuyun Liu, Dong Ming

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jiande GuoState Key Laboratory of Advanced Medical Materials and Medical Devices, Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin 300072, China.ORCID 0000-0002-2752-4774
Juan HuangInstitute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China.
Xizi SongState Key Laboratory of Advanced Medical Materials and Medical Devices, Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin 300072, China.ORCID 0000-0002-0676-3258
Chenghao HuState Key Laboratory of Acoustics and Marine Information, Institute of Acoustics, Chinese Academy of Sciences, Beijing 100190, China.
Xiuyun LiuState Key Laboratory of Advanced Medical Materials and Medical Devices, Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin 300072, China.
Dong MingState Key Laboratory of Advanced Medical Materials and Medical Devices, Academy of Medical Engineering and Translational Medicine, Medical School, Tianjin University, Tianjin 300072, China.

Funding

Major Science, Technology Special Projects and Engineering - Major Project of National Key Laboratories 24ZXZSSS00510National Key Laboratory of Sound Field and Sound Information Projects SKLA202311National Natural Science Foundation of China 62276183,82472098Shandong Provincial Natural Science Foundation Major Basic Research Project ZR2025ZD13Tianjin Natural Science Foundation-Outstanding Youth Project 24JCJQJC00250
6 · The paper itself

Abstract

Transcranial acoustoelectric brain imaging (tABI) is a potential brain activity imaging technique with high spatiotemporal resolution. Precise focus of transcranial ultrasound is critical for realizing millimeter-level spatial resolution in tABI. In this study, a precise focusing simulation platform is proposed by constructing a high-precision 3D skull model from Bama pig computed tomography data and a mathematical model equation by considering the skull's heterogeneous properties. Then, the delay parameters derived from the simulation platform improve the precision of transcranial ultrasound focusing, enabling precise localization of brain activation sources with tABI. Phantom experimental results demonstrate that the transcranial ultrasound field is precisely focused at the target with a 0.20 mm deviation when delay parameters are obtained from the proposed simulation platform, whereas it exhibits divergence when using delay parameters derived from pure water or homogeneous skull models. Furthermore, using the proposed simulation platform, tABI can accurately identify intracranial electrical signals of distinct frequencies and precisely locate the corresponding activation sources with a spatial deviation of 0.50 mm. These results demonstrate that the proposed simulation platform is a powerful tool for the precise focusing of tABI.

Indexed as

BrainAnimalsComputer SimulationPhantoms, ImagingSkullSwineacoustoelectric brain imagingprecise focusing simulation platformskulltranscranial focused ultrasound

Identifiers

PMID42122435
PMCPMC13166024

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.