A Novel Nickel-Foam/Tungsten-Powder/Epoxy-Resin Backing Material for Medical Ultrasound Transducers.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
The miniaturization of medical ultrasound imaging transducers is currently limited by the thick backing layers required to dissipate backward acoustic energy. To address this, a novel hybrid composite backing material was developed by interpenetrating a three-dimensional open-cell nickel foam skeleton with a traditional tungsten-powder/epoxy-resin matrix. Two groups of composite samples with varying pores per inch (PPI) were fabricated, and their acoustic properties were systematically characterized. Experimental results indicated that the 100 PPI composite achieved macroscopic acoustic attenuation coefficients of 62.6 dB/cm at 5 MHz and 84.2 dB/cm at 7.5 MHz. These values are roughly three times higher than conventional backing materials, while maintaining a suitable acoustic impedance of 10.81 MRayl. A 5 MHz transducer utilizing a 5.0 mm layer of this proposed backing achieved a -60 dB two-way pulse-echo insertion loss, effectively eliminating backside interference with performance comparable to a 16.5 mm conventional backing. This structural strategy successfully reduces the required backing axial dimension by over 60% without compromising transducer bandwidth, offering a viable material solution for miniaturized ultrasonic transducers.