Evidence map›Paper›PMID 42122309›Full record

ArticleSensors (Basel, Switzerland)2026

Ultrathin Temporary Tattoo Electrodes Enable Prolonged Skin-Conformable EMG Sensing for Hip Exoskeleton Control.

Michele Foggetti, Marina Galliani, Andrea Pergolini, Aliria Poliziani, Emilio Trigili, Francesco Greco, Nicola Vitiello, Laura M Ferrari, Simona Crea

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Michele FoggettiThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.
Marina GallianiThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.ORCID 0000-0003-3814-1899
Andrea PergoliniThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.
Aliria PolizianiThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.
Emilio TrigiliThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.ORCID 0000-0002-3725-5694
Francesco GrecoThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.
Nicola VitielloThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.
Laura M FerrariThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.ORCID 0000-0001-8521-9666
Simona CreaThe Biorobotics Institute, Scuola Superiore Sant'Anna, 56025 Pontedera, Italy.ORCID 0000-0001-9833-4401

Funding

Biorobotics Research and Innovation Engineering Facilities (BRIEF) IR000003Tuscany Health Ecosystem (THE) B3C22003920001
6 · The paper itself

Abstract

Conventional gel electrodes are the gold standard for surface electromyography (sEMG), yet their bulkiness, stiffness, and limited gel lifetime prevents seamless day-long integration with wearable robots. We integrated ultrathin skin-conformal temporary tattoo electrodes with a powered unilateral hip exoskeleton and compared signal quality during treadmill walking against gel. In this pilot study, five healthy participants completed three consecutive walking blocks at fixed speed: (1) using gel electrodes; (2) using tattoo electrodes to compare signal quality; and (3) using the same tattoo electrodes (not repositioned) after eight hours of wear to simulate a full day of typical device use and to evaluate potential degradation in signal quality over time. Electrodes were positioned on muscles not covered by the exoskeleton interface (tibialis anterior and gastrocnemius medialis), as well as on muscles located beneath the exoskeleton cuff, which were potentially subject to motion artifacts due to the application of external forces by the exoskeleton (rectus femoris and biceps femoris, BF). Across all muscles, for both gel and tattoo electrodes, the root mean square error (RMSE) between normalized sEMG envelopes and biological activation profile was 0.069 ± 0.048, and Pearson's correlation coefficient (

Indexed as

ElectromyographyExoskeleton DeviceHipTattooingAdultElectrodesFemaleHumansMaleMuscle, SkeletalWalkinghip exoskeletonhuman–robot interactionlong-term monitoringskin-conformal electronicssurface electromyographytattoo electronicsvolitional controlwearable devices

Identifiers

PMID42122309
PMCPMC13165618

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.