Evidence map›Paper›PMID 42121127›Full record

ArticleBMC oral health2026

Evaluation of the accuracy and reliability of two electronic apex locators using micro-computed tomography.

Hyoung-Hoon Jo, Kun-Hwa Sung, Tae-Young Park, Jeong-Bum Min, Ho-Keel Hwang

Abstract readEvaluation Study
In one paragraph

Article in BMC oral health, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hyoung-Hoon JoDepartment of Conservative Dentistry, School of Dentistry, Chosun University, 309 Pilmun- Daero, Dong-gu, Gwangju, 61452, Republic of Korea.
Kun-Hwa SungDepartment of Conservative Dentistry, College of Dentistry, Wonkwang University, Iksan, Republic of Korea.
Tae-Young ParkDepartment of Conservative Dentistry, School of Dentistry, Chosun University, 309 Pilmun- Daero, Dong-gu, Gwangju, 61452, Republic of Korea.
Jeong-Bum MinDepartment of Conservative Dentistry, School of Dentistry, Chosun University, 309 Pilmun- Daero, Dong-gu, Gwangju, 61452, Republic of Korea.
Ho-Keel HwangDepartment of Conservative Dentistry, School of Dentistry, Chosun University, 309 Pilmun- Daero, Dong-gu, Gwangju, 61452, Republic of Korea. rootcanal@hanmail.net.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThis study evaluated the accuracy and reliability of two electronic apex locators (EALs), DentaPort ZX (DTP) and EQ-Pex (EQP), at the 0.0 (APEX) and 0.5 display marks using micro-computed tomography (micro-CT), referencing the 0.0 mark to the apical foramen (AF) and the 0.5 mark to the apical constriction (AC).

methodsSixty extracted single-rooted mandibular premolars with fully formed apices were included. Preoperative micro-CT was used to identify the AF and AC and measure the AC-AF distance. Working length measurements were obtained in randomized order using a standardized mounting model. The file was fixed at the 0.0 position and scanned with micro-CT; positions corresponding to the 0.5 readings were calculated from micrometer displacement. Distances from the file tip to the AF and AC were compared using the Wilcoxon signed-rank test. Accuracy within ± 0.1, ± 0.25, and ± 0.5 mm was compared using McNemar's test. Reliability was evaluated using Bland-Altman-style plots and Levene's test.

resultsTwo specimens were excluded (n = 58). The AC was located 0.33 ± 0.12 mm coronal to the AF. At the 0.0 mark, mean distances from the AF were - 0.17 ± 0.18 mm (DTP) and - 0.14 ± 0.20 mm (EQP), with EQP closer to the AF (p = 0.045). At the 0.5 mark, mean distances from the AC were - 0.25 ± 0.27 mm (DTP) and - 0.21 ± 0.24 mm (EQP), with EQP closer to the AC (p = 0.004). Accuracy at the AF did not differ between devices. At the AC, accuracy within ± 0.5 mm was higher for DTP than EQP (89.7% vs. 77.6%, p = 0.039). Agreement was acceptable; however, variability was greater at the AC, with no significant variance differences.

conclusionsBoth EALs demonstrated acceptable accuracy and comparable reliability within ± 0.5 mm. Although a statistically significant difference in accuracy was observed at the 0.5 mark, the magnitude of the difference may have limited clinical relevance. Clinicians should interpret display marks cautiously when determining working length.

Indexed as

OdontometryRoot Canal PreparationTooth ApexX-Ray MicrotomographyBicuspidDental Pulp CavityHumansReproducibility of ResultsApical constrictionApical foramenElectronic apex locatorsMicro-computed tomographyWorking length

Identifiers

PMID42121127
PMCPMC13347877

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.