Evidence map›Paper›PMID 42120696›Full record

ReviewNature protocols2026

Fabrication of focused electron beam induced deposition tips for high-speed atomic force microscopy using benchtop scanning electron microscopy.

Motonori Imamura, Atsushi Miyagi, Alma P Perrino, Simon Scheuring

Abstract readReview
In one paragraph

Review in Nature protocols, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Motonori Imamura *Department of Anesthesiology, Weill Cornell Medicine, New York, NY, USA.
Atsushi Miyagi *Department of Anesthesiology, Weill Cornell Medicine, New York, NY, USA.
Alma P PerrinoDepartment of Anesthesiology, Weill Cornell Medicine, New York, NY, USA.
Simon ScheuringDepartment of Anesthesiology, Weill Cornell Medicine, New York, NY, USA. sis2019@med.cornell.edu.ORCID http://orcid.org/0000-0003-3534-069X

Funding

High-speed atomic force microscopy with microsecond time resolution for the study of channels and transportersR01NS110790 · NINDS · WEILL MEDICAL COLL OF CORNELL UNIV · PI Simon Scheuring · 2019 to 2026
$2.4M
Structure and Function of a Pentameric TRPV3 ChannelR01NS134559 · NINDS · WEILL MEDICAL COLL OF CORNELL UNIV · PI Simon Scheuring · 2024 to 2026
$1.8M
NINDS NIH HHS R01 NS110790NINDS NIH HHS R01 NS134559U.S. Department of Health & Human Services | NIH | National Institute of Neurological Disorders and Stroke (NINDS) R01NS110790U.S. Department of Health & Human Services | NIH | National Institute of Neurological Disorders and Stroke (NINDS) R01NS134559
6 · The paper itself

Abstract

High-speed atomic force microscopy (HS-AFM) movies have contributed significantly to our understanding of biomolecular dynamics, because these experiments have resolved conformational changes at submolecular resolution in aqueous environments. However, the resolution of HS-AFM images and AFM images in general critically depend on the sharpness of the tip. Focused electron beam-induced deposition (FEBID) in a scanning electron microscope (SEM) yields AFM tips with high aspect ratio and small tip radius, formed by deposition of metal-organic precursors such as ferrocene, producing amorphous carbon deposits, permissive for the reproducible acquisition of high-resolution images. Although FEBID tips are essential for HS-AFM image quality, it is common to rely on commercial cantilevers, because of limited SEM access or perceived technical barriers. Here, we showcase the use of a commercial benchtop SEM for the fabrication of FEBID tips for high-resolution AFM. To facilitate the fabrication process, we developed a cantilever and sample holder that minimize drift and mechanical vibrations during SEM operation and enable efficient and reproducible fabrication of sharp AFM tips. The shape of the FEBID tips was evaluated as a function of beam defocus, deposition time, acceleration voltage and beam current. We describe an optimized workflow for FEBID tip fabrication (eight tips can be fabricated within 1-2 h) and demonstrate high-resolution and long-term stable HS-AFM imaging of annexin V and plasmid DNA using the FEBID tips fabricated in this study. We anticipate that this protocol may be useful for a wide range of AFM practitioners and facilitate the reproducible acquisition of high-resolution AFM data.

Identifiers

PMID42120696
PMCPMC13334414

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.