ArticleJournal of applied clinical medical physics2026
Assessing the delivery error detection sensitivity of a new 2D detector prototype for carbon ion PSQA measurements.
Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
backgroundParticle therapy requires stringent patient-specific quality assurance (PSQA) to validate dose distributions delivered by the system. PURPOSE: This study presents preliminary results on the performance evaluation of the MatriXX AiR 2D ionization-chamber array for patient-specific QA (PSQA) in carbon-ion therapy, comparing measured and planned dose distributions.
methodsA series of 10 test cases, including a treatment plan for a box-shaped target (6-cm side length), uniformly covered by the dose and nine patient-specific treatment plans, were assessed. Measurements were conducted at two water equivalent depths using RW3 phantoms: beam entrance and within the Spread-Out Bragg Peak (SOBP). The study examined the detector's ability to detect deviations by systematically modifying treatment plans, comparing the measured and planned dose utilizing gamma index analysis.
resultsPassing rate analysis revealed depth-dependent sensitivity to treatment plan delivery modifications. Measurements at the entrance depth showed better sensitivity to delivery changes than those taken within the SOBP
conclusionsThe MatriXX AiR detector demonstrated strong potential for PSQA in carbon ion therapy. These findings support its application in clinical workflows to enhance treatment verification and accuracy.