Evidence map›Paper›PMID 42120318›Full record

ArticleJournal of applied clinical medical physics2026

Characterization of a novel plastic scintillation detector for in vivo electron dosimetry.

Cornelius J Bauer, Frank Schneider, Ida D Göbel, Hans Oppitz, Frank A Giordano, Jens Fleckenstein

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Cornelius J BauerDepartment of Radiation Oncology, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany.ORCID https://orcid.org/0000-0002-8736-3431
Frank SchneiderDepartment of Radiation Oncology, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany.
Ida D GöbelDepartment of Radiation Oncology, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany.
Hans OppitzDepartment of Radiation Oncology, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany.
Frank A GiordanoDepartment of Radiation Oncology, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany.
Jens FleckensteinDepartment of Radiation Oncology, University Medical Centre Mannheim, Heidelberg University, Mannheim, Germany.ORCID https://orcid.org/0000-0002-7321-6457

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionReal-time dosimetry of surface doses in electron beams has not been widely established yet. Plastic scintillation detectors (PSDs) promise high spatial resolution and real-time dosimetry with minimum perturbation of the radiation field. This study characterizes a novel PSD in an electron beam to determine its suitability for in vivo dosimetry.

methodsDual-channel Cherenkov radiation correction and dosimetric characterization of the PSD were investigated using reference ionization chambers. Percentage depth-dose curves, lateral profiles, and output factors were compared with reference ionization chamber measurements. Surface doses were measured on solid water and on an anthropomorphic phantom and were compared to ionization chamber and radiochromic film measurements.

resultsThe investigated PSD demonstrated clinically acceptable linearity, dose rate independence, isotropy and reproducibility (total variation < 2%). Dosimetric deviations in R

conclusionThe PSD investigated in this study is suitable for clinically acceptable electron beam dosimetry and provides accurate dosimetric results for surface dose measurements. It has the potential to be used for real-time in vivo dosimetry.

Indexed as

ElectronsPhantoms, ImagingPlasticsRadiometryRadiotherapy Planning, Computer-AssistedScintillation CountingHumansParticle AcceleratorsRadiotherapy DosageReproducibility of ResultsPlasticsdosimetryelectron beamplastic scintillation detectorsurface dose

Identifiers

PMID42120318
PMCPMC13167252

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.