Evidence map›Paper›PMID 42118398›Full record

Observational studyEuropean journal of pediatrics2026

Wheeze detection in real-world pediatric care: AI applied to smartphone lung auscultation.

Inês Pais-Cunha, Diogo Pessoa, Maria Catarina Silva, Henrique Ferreira-Cardoso, Bruno Rocha, Rui Pedro Paiva, Paulo de Carvalho, João A Fonseca, Inês Azevedo, Cristina Jácome

Abstract readObservational Study
In one paragraph

Observational study in European journal of pediatrics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Inês Pais-CunhaServiço de Pneumologia Pediátrica, UAG da Mulher e da Criança, ULS São João, Porto, Portugal.
Diogo PessoaCentre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.
Maria Catarina SilvaRISE-Health, MEDCIDS-Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal, University of Porto, Porto, Portugal, R. Dr. Plácido da Costa, 4200-450, Porto.
Henrique Ferreira-CardosoRISE-Health, MEDCIDS-Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal, University of Porto, Porto, Portugal, R. Dr. Plácido da Costa, 4200-450, Porto.
Bruno RochaCentre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.
Rui Pedro PaivaCentre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.
Paulo de CarvalhoCentre for Informatics and Systems of the University of Coimbra, Department of Informatics Engineering, University of Coimbra, Coimbra, Portugal.
João A FonsecaRISE-Health, MEDCIDS-Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal, University of Porto, Porto, Portugal, R. Dr. Plácido da Costa, 4200-450, Porto.
Inês AzevedoServiço de Pneumologia Pediátrica, UAG da Mulher e da Criança, ULS São João, Porto, Portugal.
Cristina JácomeRISE-Health, MEDCIDS-Department of Community Medicine, Information and Health Decision Sciences, Faculty of Medicine, University of Porto, Porto, Portugal, University of Porto, Porto, Portugal, R. Dr. Plácido da Costa, 4200-450, Porto. cristinajacome.ft@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Smartphone-based lung auscultation, combined with artificial intelligence (AI), may offer a promising alternative for pediatric respiratory telemonitoring. The aim of our study was to evaluate the performance of an AI model on wheeze detection from pediatric respiratory sounds recorded via smartphone. An observational cross-sectional study was conducted at the Pediatric Department of a Portuguese tertiary hospital, including children aged 0-17 years (pre-school, school-aged, and adolescent), with or without respiratory disease. Respiratory sounds were recorded at four locations using smartphone microphones and independently classified by at least 2 blinded annotators for quality and presence of wheezes. A hybrid convolutional-recurrent neural network (CNN + LSTM) trained on public electronic stethoscope databases was used to detect wheezes. AI model performance was assessed using positive predictive value, sensitivity, specificity, accuracy, and F1-score. A total of 217 children (59.9% male; median 10 [Q1-Q3 4.5-13] years) were included. From 2020 respiratory sound recordings, 1500 (74.3%) met quality criteria. Manual annotation identified 271 recordings with wheezes, whereas AI detected 217, most frequently in pre-school children (64.5% AI; 53.9% manual). The model achieved an overall accuracy of 87% (95% CI 86-89) and an F1-score of 61% (95% CI 56-66). The best accuracy was found in adolescents (92%, 95% CI 90-94) and the best global F1-score in pre-school children recordings (64%, 95% CI 58-71).

conclusionThis study supports the feasibility of AI-assisted analysis of smartphone-recorded pediatric respiratory sounds in real-world settings. Future multicenter studies with larger datasets and model fine-tuning using smartphone recordings are expected to improve AI model performance and generalizability. WHAT IS KNOWN: • Continuous monitoring of pediatric respiratory diseases is essential to improve outcomes and reduce healthcare and family burden. • Smartphone lung auscultation is feasible in children  but AI wheeze detection models have only been applied to recordings from electronic stethoscopes. WHAT IS NEW: • First study applying an AI model to detect wheezes in smartphone-recorded lung sounds. • Quality recordings were obtained across all pediatric age groups and the AI model performance showed promising results, comparable to studies using electronic stethoscopes.

Indexed as

Artificial IntelligenceAuscultationRespiratory SoundsSmartphoneAdolescentChildChild, PreschoolCross-Sectional StudiesFemaleHumansInfantInfant, NewbornMaleSensitivity and SpecificityArtificial intelligenceAuscultationPediatricsRespiratory soundsSmartphoneTelemonitoring

Identifiers

PMID42118398
PMCPMC13167856

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.