Evidence map›Paper›PMID 42117766›Full record

Observational studyCatheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions2026

Prognostic Impact of Pacemaker Implantation in Transcatheter Aortic Valve Replacement With Self-Expanding Prosthesis.

Francesco De Felice, Luca Paolucci, Marco Stefano Nazzaro, Carmine Musto, Diana Chin, Rocco Stio, Mauro Pennacchi, Domenico Gabrielli, Mauro Massussi, Giuliano Chizzolla and 15 more

Abstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

25 authors.

Francesco De FeliceDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.ORCID https://orcid.org/0000-0002-6369-3006
Luca PaolucciDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.ORCID https://orcid.org/0009-0000-3290-4053
Marco Stefano NazzaroDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Carmine MustoDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Diana ChinDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Rocco StioDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Mauro PennacchiDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Domenico GabrielliDivision of Interventional Cardiology, Azienda Ospedaliera S. Camillo Forlanini, Rome, Italy.
Mauro MassussiCardiac Catheterization Laboratory and Cardiology, ASST Spedali Civili di Brescia, Brescia, Italy.ORCID https://orcid.org/0000-0003-0895-440X
Giuliano ChizzollaCardiac Catheterization Laboratory and Cardiology, ASST Spedali Civili di Brescia, Brescia, Italy.
Marianna AdamoInstitute of Cardiology, ASST Spedali Civili di Brescia, Department of Medical and Surgical Specialties, Radiological Sciences, and Public Health, University of Brescia, Brescia, Italy.
Marco De CarloInterventional Cardiology Section, Cardiothoracic and Vascular Department, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.ORCID https://orcid.org/0000-0002-5763-9804
Cristina GianniniInterventional Cardiology Section, Cardiothoracic and Vascular Department, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.
Giulia CostaInterventional Cardiology Section, Cardiothoracic and Vascular Department, Azienda Ospedaliero-Universitaria Pisana, Pisa, Italy.
Antonio SisinniDepartment of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy.ORCID https://orcid.org/0000-0002-0810-6032
Luca TestaDepartment of Clinical and Interventional Cardiology, IRCCS Policlinico San Donato, Milan, Italy.ORCID https://orcid.org/0000-0003-4687-3686
Barbara BelliniSchool of Medicine, Vita-Salute San Raffaele University, Milan, Italy.
Matteo MontorfanoInterventional Cardiology Unit, IRCCS San Raffaele Scientific Institute, Milan, Italy.ORCID https://orcid.org/0000-0001-9732-9459
Giuseppe BruschiCardiac Surgery, De Gasperis Cardio Center, Niguarda Hospital, Milan, Italy.
Bruno MerlantiCardiac Surgery, De Gasperis Cardio Center, Niguarda Hospital, Milan, Italy.
Arnaldo PoliInterventional Cardiology Unit, Legnano Civil Hospital, Legnano, Italy.
Erica FerraraInterventional Cardiology Unit, Legnano Civil Hospital, Legnano, Italy.
Tiziana AttisanoCardioThoracic -Vascular Department, University Hospital San Giovanni di Dio e Ruggi d'Aragona, Salerno, Italy.ORCID https://orcid.org/0000-0002-2864-2756
Tullio PalmeriniCardiology Unit, Cardiac Thoracic and Vascular Department, IRCCS Azienda Ospedaliero-Universitaria di Bologna and Cardiac Thoracic and Vascular Department, Università di Bologna, Bologna, Italy.
Damiano RegazzoliHumanitas Research Hospital IRCCS, Milan, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWith the progressively increasing number of low-risk patients undergoing transcatheter aortic valve replacement (TAVR), the number of those who will be long-time pacemaker (PM) carriers is expected to increase. To date, conflicting data is available regarding the association between PM and mortality following TAVR.

aimsTo investigate the association between PM and mortality in patients undergoing TAVR with self-expandable bio-prosthesis.

methodsPatients undergoing TAVR between 2007 and 2014 in 10 Italian centers were considered. Two analyses were performed: one comparing patients with and without pre-TAVR PM (primary) and one comparing those with and without post-TAVR PM (secondary). The primary endpoint was all-cause mortality; the secondary endpoint was re-hospitalization to the cardiac ward. Clinical outcomes were assessed at the longest available follow-up.

resultsOverall, 1779 patients were included in the primary analysis and 1465 in the secondary one. Pre-TAVR PM implantation was not associated with an increased risk of all cause death in both the primary (adj. HR 0.93, 95% CI 0.76-1.13; p = 0.475) and secondary analysis (adj. HR 0.83, 95% CI 0.71-0.98; p = 0.029). Regarding hospitalization to cardiac ward, pre-TAVR PM was not associated with the outcome (adj. HR 1.10, 95% CI 0.85-1.42, p = 0.254), while post-TAVR PM implantation was related with an increased risk (adj. HR 1.94, 95% CI 1.56-2.41; p < 0.001).

conclusionsPM implantation is not associated with an increased risk of mortality in patients undergoing TAVR.

Indexed as

Aortic ValveAortic Valve StenosisArrhythmias, CardiacBioprosthesisCardiac Pacing, ArtificialHeart Valve ProsthesisPacemaker, ArtificialTranscatheter Aortic Valve ReplacementAgedAged, 80 and overFemaleHumansItalyMalePatient ReadmissionProsthesis DesignmortalitypacemakerTAVR

Identifiers

PMID42117766
PMCPMC13432617

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.