Evidence map›Paper›PMID 42116865›Full record

ArticleJournal of neuroendovascular therapy2026

Ruptured Internal Carotid Artery-Ophthalmic Artery Aneurysm Associated with Medial Deviation of the Internal Carotid Artery at the C2 Segment: A Case Report.

Seigo Kimura, Shigeru Miyachi, Keiichi Yamada, Ryokichi Yagi, Norihito Fukawa, Daiji Ogawa, Hirokatsu Taniguchi, Masahiko Wanibuchi

Abstract readCase Reports
In one paragraph

Article in Journal of neuroendovascular therapy, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Seigo KimuraDepartment of Neurosurgery, Kouzenkai Yagi Neurosurgical Hospital, Osaka, Osaka, Japan.
Shigeru MiyachiDepartment of Neurological Surgery, Aichi Medical University Hospital, Nagakute, Aichi, Japan.
Keiichi YamadaDepartment of Neurosurgery, Kouzenkai Yagi Neurosurgical Hospital, Osaka, Osaka, Japan.
Ryokichi YagiDepartment of Neurosurgery and Endovascular Therapy, Osaka Medical and Pharmaceutical University Hospital, Takatsuki, Osaka, Japan.
Norihito FukawaDepartment of Neurosurgery, Kouzenkai Yagi Neurosurgical Hospital, Osaka, Osaka, Japan.
Daiji OgawaDepartment of Neurosurgery, Kouzenkai Yagi Neurosurgical Hospital, Osaka, Osaka, Japan.
Hirokatsu TaniguchiDepartment of Neurosurgery, Kouzenkai Yagi Neurosurgical Hospital, Osaka, Osaka, Japan.
Masahiko WanibuchiDepartment of Neurosurgery and Endovascular Therapy, Osaka Medical and Pharmaceutical University Hospital, Takatsuki, Osaka, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: We report a ruptured internal carotid artery-ophthalmic artery (ICA-OphA) aneurysm in which morphological variation of the C2 segment, including marked medial deviation of the ICA, was suggested to be associated with aneurysm formation and may have influenced the endovascular strategy. Case Presentation: A 52-year-old woman presented with subarachnoid hemorrhage. CTA revealed a right ICA-OphA aneurysm accompanied by pronounced medial deviation of the right ICA at the C2 segment. This deviation created an acutely angled ICA-OphA bifurcation, with the OphA originating from the medial aspect of the ICA. Emergency coil embolization was performed, and the aneurysm was successfully occluded. Conclusion: The patient exhibited well-developed anterior clinoid process and optic strut morphology, which may have contributed to medial deviation of the ICA and to aneurysm formation at the ICA-OphA bifurcation. Recognition of such morphological variations is important because they may obscure OphA visualization and affect device selection. In these settings, preshaped S-type microcatheters may facilitate stable catheterization and safe coil embolization.

Indexed as

anterior clinoid processmedial deviationophthalmic artery aneurysmoptic strutpreshaped S-type microcatheter

Identifiers

PMID42116865
PMCPMC13157998

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.