Evidence map›Paper›PMID 42116206›Full record

ArticleJournal of orthopaedic surgery and research2026

Coupled experimental-computational study of Lapidus plates for the high-performance of surgical techniques for hallux hypermobility correction.

Natali Mancera-Campos, L Padrón-Cabrera, M Llorens-Eizaguerri, J A Bea, A Vidal-Lesso, J Bayod-López

Abstract read
In one paragraph

Article in Journal of orthopaedic surgery and research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Natali Mancera-CamposDepartment of Mechanical Engineering, Universidad de Guanajuato, Salamanca, Mexico. n.manceracampos@ugto.mx.ORCID http://orcid.org/0000-0002-9690-8480
L Padrón-CabreraDepartment of Mechanical Engineering, Universidad de Zaragoza , Zaragoza, Spain.ORCID http://orcid.org/0000-0002-5146-4118
M Llorens-EizaguerriDepartment of Traumatology and Orthopedics, Faculty of Medicine, Universidad de Zaragoza, Zaragoza, Spain.
J A BeaAragon Institute of Engineering (I3A), Universidad de Zaragoza, Zaragoza, Spain.
A Vidal-LessoDepartment of Mechanical Engineering, Universidad de Guanajuato, Salamanca, Mexico.ORCID http://orcid.org/0000-0002-7594-1927
J Bayod-LópezApplied Mechanics and Bioengineering Group (AMB), Aragon Institute of Engineering Research (I3A), Universidad de Zaragoza, Zaragoza, Spain.

Funding

Ministerio de Ciencia e Innovación PID2023-149353OB-I00
6 · The paper itself

Abstract

backgroundFor the correction of Hallux hypermobility through surgery, Lapidus plates have been studied as surgical fixation devices to evaluate the procedure's success and its implications for biomechanical foot performance. However, significant knowledge gaps persist regarding the behavior of these devices and their biomechanical characteristics following implantation.

methodsThis work studies two types of Lapidus plates through a coupled experimental-computational analysis. The first is a plantar fixation device, and the second is a helical device; both are used as fixation tools in Cuneometatarsal Arthrodesis. For this, mechanical tests specifically compression and fatigue are conducted with specimens of cadaveric feet implanted in the first cuneometatarsal joint (FCMJ) with each of the Lapidus plates. To the knowledge of this research team, for the first time reported in literature, complete foot specimens are used for the experimental tests. At the same time, numerical foot models have been developed to generate numerical data validated against experimental results. This approach enables the identification of additional structural information, through numerical methods, which is then complemented by electron microscopy analyses of the plates after experimental testing.

resultsThe highest micro-deformation was found in the first metatarsal of the foot with a helical plate ([Formula: see text] mm/mm) and in the fifth metatarsal of the foot with a plantar plate ([Formula: see text] mm/mm). Both numerical and experimental analyses agreed within 98%. A correction of Hallux hypermobility up to 82.28% was achieved with the Lapidus arthrodesis, and bone failure was recorded at forces of 425 N and 275 N at the helical and plantar insertions, respectively.

conclusionsThe results suggest that the Lapidus plate's helical configuration is superior, both structurally and functionally, to the plantar-only configuration, indicating that multi-planar fixation provides better mechanical stability than single-plane plantar fixation.

Indexed as

ArthrodesisBone PlatesComputer SimulationHalluxJoint InstabilityBiomechanical PhenomenaCadaverHumansMetatarsal BonesArthrodesisCuneometatarsal fixationFoot biomechanicsLapidus constructionNumerical analysis