Evidence map›Paper›PMID 42116086›Full record

ArticleBMC veterinary research2026

Ultrasound measurement of the optic nerve and its sheath using the CLOSED protocol: comparison with MRI in a porcine in-vivo model.

Ludwika Gąsior, Przemysław Prządka, Mateusz Hebel, Kamil Suliga, Agnieszka Antończyk

Abstract readComparative Study
In one paragraph

Article in BMC veterinary research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Ludwika GąsiorDepartment and Clinic of Surgery, Faculty of Veterinary Medicine, Wrocław University of Environmental and Life Sciences, Wrocław, Poland. ludwika.gasior@upwr.edu.pl.
Przemysław PrządkaDepartment and Clinic of Surgery, Faculty of Veterinary Medicine, Wrocław University of Environmental and Life Sciences, Wrocław, Poland.
Mateusz HebelDepartment and Clinic of Surgery, Faculty of Veterinary Medicine, Wrocław University of Environmental and Life Sciences, Wrocław, Poland.
Kamil SuligaDepartment and Clinic of Surgery, Faculty of Veterinary Medicine, Wrocław University of Environmental and Life Sciences, Wrocław, Poland.
Agnieszka AntończykDepartment and Clinic of Surgery, Faculty of Veterinary Medicine, Wrocław University of Environmental and Life Sciences, Wrocław, Poland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFinding a reliable, non-invasive method for assessing intracranial pressure in humans and other species remains a subject of ongoing scientific and clinical interest. Ultrasonographic measurement of the optic nerve and its sheath shows considerable promise and is widely used in human medicine. However, methodological challenges must be addressed when applying this approach in animal models. The aim of this study was to evaluate whether a previously developed ultrasonographic protocol is feasible under in vivo conditions in pigs and whether the obtained measurements accurately reflect anatomical dimensions. To this end, transbulbar ultrasonographic examinations were performed in sixteen pigs under general anesthesia, and optic nerve and optic nerve sheath diameters were measured in the left eye and compared with corresponding magnetic resonance imaging measurements. All measurements were performed twice and averaged.

resultsUltrasonographic visualization of the optic nerve and its sheath was feasible in all animals, and accurate measurement points corresponding to the borders of these structures were established. Measurements obtained using ultrasonography showed good agreement with magnetic resonance imaging, with no significant differences between modalities (p > 0.05) and all measurements within the 95% limits of agreement. The mean optic nerve diameter was 3.26 mm for sonographic measurement and 3.18 mm for magnetic resonance measurement, while the mean optic nerve sheath diameter was 5.12 mm and 5.36 mm, respectively.

conclusionsThese findings indicate that the standardized ultrasonographic protocol can be successfully applied in a porcine in vivo model and provides anatomically reliable measurements. This methodological validation represents an important step toward future experimental studies investigating intracranial pressure-related changes, for example during laparoscopic procedures.

Indexed as

Magnetic Resonance ImagingOptic NerveAnimalsFemaleSwineUltrasonographyCLOSED protocolMagnetic resonance imagingOptic nerve diameterOptic nerve sheath diameterPorcineUltrasound

Identifiers

PMID42116086
PMCPMC13335286

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.