Evidence map›Paper›PMID 42115680›Full record

ArticleScientific reports2026

Deep learning-based automatic field of view planning for prostate MRI in oblique coronal and oblique axial planes.

Anton Sheahan Quinsten, Axel Wetter, Maciej Raczkowski, Łukasz Trembecki, Tomasz Guz, Samuel Oliveira, Rüdiger Buchkremer, David Matusiewicz, Kai Nassenstein, Michael Forsting and 1 more

Abstract readMulticenter Study
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Anton Sheahan QuinstenInstitute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany. anton.quinsten@uk-essen.de.ORCID http://orcid.org/0000-0001-8168-8406
Axel WetterAsklepios Clinic Hamburg, Hamburg, Germany.
Maciej RaczkowskiDepartment of Oncology, Wroclaw Medical University, pl. L. Hirszfelda 12, Wroclaw, 53-413, Poland.
Łukasz TrembeckiDepartment of Oncology, Wroclaw Medical University, pl. L. Hirszfelda 12, Wroclaw, 53-413, Poland.
Tomasz GuzMicro Solutions, Sp. z o.o, ul. Legnicka 55f, Wrocław, 54-203, Poland.
Samuel OliveiraEverything MRI, London, UK.
Rüdiger BuchkremerInstitute of IT Management and Digitization Research (ifid), FOM University, Düsseldorf, Germany.
David MatusiewiczInstitute for Health & Social Science (ifgs), FOM University, Essen, Germany.
Kai NassensteinInstitute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.
Michael ForstingInstitute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.
Aydin DemircioğluInstitute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147, Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate field-of-view (FoV) prescription in oblique coronal and axial planes is essential for high-quality prostate MRI but remains operator-dependent and variable. We developed and evaluated a ResNet-based deep learning framework for automated FoV planning. In this retrospective multicenter study, FoV prescriptions were annotated on PI-CAI dataset. Three readers assessed intra- and inter-rater variability to establish reference consistency. Three neural network variants were trained on 1,474 examinations from PI-CAI dataset (2012-2021), and the optimal model was selected by internal validation. Generalizability and clinical utility were tested on three external cohorts totaling 530 examinations (2021-2024) using a non-inferiority design. The selected model achieved non-inferior performance for slice positioning, with differences ranging from 0.16 ± 0.99 to 0.37 ± 0.48. Across sites, FoV overlaps ranged from 82.4 ± 4.1% to 88.7 ± 6.0%, and the angle differences between predicted and reference planes were 4.66 ± 4.89° (Site I), 3.46 ± 2.80° (Site II), and 2.99 ± 2.90° (Site III). Clinical utility was high at all sites, with acceptability rates of 97.9%, 97.7%,98.8%, 98.1% and 98.1% for Site I (Raters 1-5), 95.7%, 97.8%, 100%, 95.7% and 97.8% for Site II (Raters 1-5), and 100% for all raters at Site III. These findings demonstrate the feasibility of automated FoV positioning for prostate MRI and indicate excellent clinical utility.

Indexed as

Deep LearningImage Processing, Computer-AssistedMagnetic Resonance ImagingProstateProstatic NeoplasmsHumansMaleRetrospective StudiesautomationDeep LearningField of viewProstate cancerProstate MRI

Identifiers

PMID42115680
PMCPMC13161440

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.