Evidence map›Paper›PMID 42114129›Full record

ArticleInterdisciplinary cardiovascular and thoracic surgery2026

Left Ventricular Outflow Tract Diameter Variability and Prosthesis-Patient Mismatch: A Simulation Study.

J W Taco Boltje, Bart J J Velders, Joseph F Sabik, Jae K Oh, Saki Ito, Robert J M Klautz, Michiel D Vriesendorp

Abstract read
In one paragraph

Article in Interdisciplinary cardiovascular and thoracic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

J W Taco BoltjeDepartment of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands.ORCID 0009-0005-4646-4059
Bart J J VeldersDepartment of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands.ORCID 0000-0002-3999-4220
Joseph F SabikDepartment of Surgery, University Hospitals, Case Western Reserve University School of Medicine, Cleveland, OH 44106-7060, United States.
Jae K OhDepartment of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905-0001, United States.
Saki ItoDepartment of Cardiovascular Medicine, Mayo Clinic, Rochester, MN 55905-0001, United States.ORCID 0000-0001-7076-2340
Robert J M KlautzDepartment of Cardiothoracic Surgery, Leiden University Medical Center, Leiden 2333 ZA, The Netherlands.ORCID 0000-0002-6507-3855
Michiel D VriesendorpDepartment of Cardiothoracic Surgery, Amsterdam University Medical Center, Amsterdam 1105 AZ, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A recent discussion that highlighted the differences between the reported effective orifice area and corresponding incidence of prosthesis-patient mismatch within the 1- and 7-year results of the PERIcardial SurGical AOrtic Valve ReplacemeNt (PERIGON) Trial of the Avalus valve has once again emphasized the instability of such measurements. The effective orifice area, calculated using the continuity equation through measurements of the left ventricular outflow tract diameter, is highly susceptible to measurement variability, as previously demonstrated in literature through both intra- and interobserver variability. To illustrate this problem, a simulation was performed in which the left ventricular outflow tract diameter was systematically altered by -2 mm, -1 mm, 0 mm, +1 mm, and +2 mm. Subsequently, the proportion of severe prosthesis-patient mismatch was recalculated and varied between 13.3%, 6.2%, 3.1% (original), 1.2%, and 0.3%, respectively. These findings demonstrate that small but clinically realistic variability in left ventricular outflow tract measurements can significantly affect the presence of prosthesis-patient mismatch. A measurement variability of 1 mm can nearly double or halve the prevalence of severe prosthesis-patient mismatch. This illustrates that prosthesis-patient mismatch, in its current form, is highly unstable and that indexed effective orifice area-based prosthesis-patient mismatch should not be used in isolation.

Indexed as

Aortic ValveBioprosthesisComputer SimulationHeart Valve ProsthesisHeart Valve Prosthesis ImplantationHeart VentriclesModels, CardiovascularHumansProsthesis Designaortic valve replacementechocardiographyleft ventricular outflow tract diametermeasurement variabilityprosthesis-patient mismatch

Identifiers

PMID42114129
PMCPMC13198365

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.