Evidence map›Paper›PMID 42113768›Full record

ArticlePloS one2026

Single dynamic structured light navigation for minimally invasive cervical pedicle screw insertion: Achieving complex design and precise puncture.

Xuanhuang Chen, Xiaoxia Huang, Guodong Zhang, Kaijun Li, Qi Liu, Zaopeng He, Weihong Xu

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xuanhuang ChenDepartment of Spinal Surgery, the First Affiliated Hospital, Fujian Medical University, Fuzhou, China.
Xiaoxia HuangDepartment of Spinal Surgery, the First Affiliated Hospital, Fujian Medical University, Fuzhou, China.
Guodong ZhangLecong Hospital of Shunde, Foshan, China.
Kaijun LiLecong Hospital of Shunde, Foshan, China.
Qi LiuDepartment of Orthopedics, the Affiliated Hospital of Putian University, Putian, China.
Zaopeng HeLecong Hospital of Shunde, Foshan, China.
Weihong XuDepartment of Spinal Surgery, the First Affiliated Hospital, Fujian Medical University, Fuzhou, China.ORCID https://orcid.org/0000-0001-9490-8500

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimThe aim of this study was to explore the preoperative design and intraoperative navigation for minimally invasive cervical pedicle punctures and to validate the feasibility and accuracy of a single dynamic structured light navigation system.

methodsNine bovine cervical spine bone models were created for preoperative CT scanning and three-dimensional reconstruction. Preoperative segmentation of the vertebral bodies and design of the navigation channels were conducted. During the procedure, structured light scanning was employed to capture the intraoperative scene and facilitate registration. The navigation channel was adjusted to align with the preoperative design. A 2.0 mm stainless steel Kirschner wire was subsequently inserted into each pedicle through separate punctures. The position of the Kirschner wire was evaluated via the Neo classification system. Intraoperative root mean square (RMS) values and registration accuracy were recorded. The deviations and angles of the preoperative and postoperative entry and exit points were calculated on the basis of the three-dimensional coordinates of these points. Statistical analyses were performed to assess differences in the X, Y, and Z coordinate values of the entry and exit points before and after the procedure.

resultsA total of 124 Kirschner wires were inserted, and the Neo classification evaluation for all models was Grade 0, with a puncture accuracy of 100%. There was high consistency between the postoperative Kirschner wire trajectories and the preoperative design. The average intraoperative RMS and registration accuracies were 0.424 ± 0.12 mm and 0.01 ± 0.008 mm, respectively. The preoperative and postoperative entry point deviation was 0.904 ± 0.419 mm, and the exit point deviation was 1.253 ± 0.607 mm. The entry and exit point deviation angle was 0.918 ± 0.421°. The deviation may be related to bone surface factors.

conclusionA single dynamic structured light navigation system is capable of performing simultaneous preoperative complex design, intraoperative scene scanning, static registration, and dynamic tracking of piercing instruments, thereby enabling high-precision minimally invasive punctures.

Indexed as

Cervical VertebraeMinimally Invasive Surgical ProceduresPedicle ScrewsSurgery, Computer-AssistedAnimalsBone WiresCattleImaging, Three-DimensionalPuncturesTomography, X-Ray Computed

Identifiers

PMID42113768
PMCPMC13160301

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.