ArticleMedical physics2026

A parallel algorithm for generating Pareto-optimal radiosurgery treatment plans.

Joakim da Silva, Daniel Hernández Escobar, Tor Kjellsson Lindblom, Håkan Nordström, Jens Sjölund

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Joakim da SilvaElekta Instrument AB, Stockholm, Sweden.
Daniel Hernández EscobarDepartment of Information Technology, Uppsala University, Uppsala, Sweden.
Tor Kjellsson LindblomElekta Instrument AB, Stockholm, Sweden.
Håkan NordströmElekta Instrument AB, Stockholm, Sweden.
Jens SjölundDepartment of Information Technology, Uppsala University, Uppsala, Sweden.

Funding

Knut and Alice Wallenberg FoundationSweden's Innovation Agency 2022-03023
6 · The paper itself

Abstract

backgroundUsing inverse planning tools to create radiosurgery treatment plans is an iterative process, where clinical trade-offs are explored by changing the relative importance given to different objectives and rerunning the optimizer until a desirable plan is found. Simultaneously generating many plans corresponding to different objective weights, while the patient is awaiting treatment, would allow the planner to navigate clinical trade-offs interactively, without optimizing a new plan between each update. PURPOSE: We seek to optimize hundreds of Gamma Knife radiosurgery treatment plans, corresponding to different weightings of objectives, fast enough to allow interactive Pareto navigation of clinical trade-offs to be incorporated into the clinical workflow.

methodsWe apply the alternating direction method of multipliers (ADMM) to the linear-program formulation of the optimization problem used in the clinical Lightning optimizer. We implement both a CPU and a GPU version of ADMM in Matlab and compare them to Matlab's built-in, single-threaded dual-simplex solver. The ADMM implementation is adapted to the optimization procedure used in the clinical software, with a bespoke algorithm for maximizing the overlap between low-dose points for different objective weights. The method is evaluated on a test dataset consisting of 20 cases from three different indications, with between one and nine targets and total target volumes ranging from 0.66 to 52 cm

resultsThe total optimization time to create 81 plans corresponding to different objective weightings varied from 63 to 520 s on CPU and from 1.8 to 40 s GPU, for the different test cases. As a reference, optimizing 81 plans using simplex took 100-51000 s, corresponding to ADMM speedups of 1.6-97 and 54-1500 times for the CPU and GPU, respectively. Increasing the number of plans to 441, corresponding to all combinations of slider values between 0.0 and 1.0 in steps of 0.05 in the clinical software, the total ADMM optimization time on GPU was between 3.0 and 110 s for the different test cases. Plan quality was evaluated by rerunning the ADMM optimization 20 times, each with a different random seed, for each test case and for nine objective weightings per case. The resulting relative differences in clinical metrics (

conclusionsWe show how ADMM can be adapted for radiosurgery plan optimization, allowing hundreds of high-quality Gamma Knife treatment plans to be created in under two minutes on a single GPU, also for very large cases. The presented method would allow streamlined multicriteria optimization on the day of treatment, with interruption-free navigation of clinical trade-offs.

Indexed as

AlgorithmsRadiosurgeryRadiotherapy Planning, Computer-AssistedHumansParallel AlgorithmsRadiotherapy DosageSoftwareGPUmulticriteria optimizationradiosurgery

Identifiers

PMID42108219
PMCPMC13158170

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.