Evidence map›Paper›PMID 42103998›Full record

ArticleSkeletal radiology2026

Ultrasound gap measurement after acute Achilles rupture is reliable overall but uncertain near a 5-mm decision threshold.

Dan Mocanu, Katarzyna Bokwa-Dąbrowska, Elin Larsson, Katarina Nilsson Helander, Pawel Szaro

Abstract read
In one paragraph

Article in Skeletal radiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dan MocanuDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborgsvägen 31, 431 80, Gothenburg, Sweden.
Katarzyna Bokwa-DąbrowskaDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborgsvägen 31, 431 80, Gothenburg, Sweden.
Elin LarssonThe Department of Orthopedics, Sahlgrenska University Hospital Mölndal, Göteborgsvägen 31, 431 80, Gothenburg, Sweden.
Katarina Nilsson HelanderThe Department of Orthopedics, Sahlgrenska University Hospital Mölndal, Göteborgsvägen 31, 431 80, Gothenburg, Sweden.
Pawel SzaroDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Göteborgsvägen 31, 431 80, Gothenburg, Sweden. pawel.szaro@gu.se.ORCID http://orcid.org/0000-0002-0334-7232

Funding

ALF ALFBGB-1006741ALF ALFGBG-1006741Centrum för idrottsforskning P2024-0126
6 · The paper itself

Abstract

objectiveUltrasound gap distance has been proposed as a supportive triage input within protocol-based pathways after acute Achilles tendon rupture. We assessed intra-/inter-rater reliability of gap measurement and the extent of classification uncertainty around a 5-mm threshold. Retrospective observer-agreement study without a definitive reference standard, using protocol-acquired stored ultrasound cine loops from 30 clinically diagnosed complete acute ruptures in a prospectively collected cohort.

methodsRetrospective observer-agreement study without a definitive reference standard, using protocol-acquired stored ultrasound cine loops from 30 clinically diagnosed complete acute ruptures in a prospectively collected cohort. Two blinded musculoskeletal radiologists re-reviewed stored cine loops and measured tendon-gap distance in two sessions each (≥ 4 weeks apart). We calculated intraclass correlation coefficients (ICC), Bland-Altman mean difference and 95% limits of agreement (LoA), and standard error of measurement (SEM). Agreement at the 5-mm protocol cut-point was assessed using Cohen's κ and Gwet's AC1. Using SEM, we derived 90% confidence zones indicating firm classification versus a grey zone where repeat measurement or second read may be considered.

resultsIntra-rater ICC(2,1) was 0.88 (95% CI 0.83-0.91) and 0.94 (0.82-0.97); SEMs were 1.57 and 1.19 mm. Inter-rater bias was + 1.12 mm with LoA - 3.85 to 6.10 mm. Agreement for study experimental pathway classification at the 5-mm cut-point (operative vs non-operative) was moderate (κ = 0.60; AC1 = 0.61), with 6/30 examinations classified differently. SEM-based 90% zones were ≤ 2.42 and ≥ 7.58 mm (rater 1) and ≤ 3.04 and ≥ 6.96 mm (rater 2); a conservative cross-rater rule suggested ≤ 2.05 or ≥ 7.95 mm.

conclusionGap measurement shows good relative reliability, but uncertainty near 5 mm can alter classification. Reporting LoA/SEM alongside ICC and flagging a grey zone may reduce misclassification in borderline cases.

Indexed as

Achilles TendonTendon InjuriesFemaleHumansMaleObserver VariationReproducibility of ResultsRetrospective StudiesRuptureUltrasonographyAchilles tendon ruptureDecision thresholdInterobserver reliabilityIntraclass correlation coefficientTendon gap measurementUltrasonography

Identifiers

PMID42103998
PMCPMC13369784

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.