A practical method for measuring rotation angles in partial-angle CT scan by using CTDI phantoms, metal rods, and a real-time dosimeter.

Hironori Otsubo, Tomonobu Haba, Yusei Nishihara, Masanao Kobayashi, Rei Ito, Yoshiki Sunada, Tomoya Ishida, Haruki Ibamoto, Shigeki Kobayashi

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hironori OtsuboGraduate School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Tomonobu HabaSchool of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake- cho, Toyoake, Aichi, 470-1192, Japan. habatomo@fujita-hu.ac.jp.ORCID http://orcid.org/0000-0002-5257-6162
Yusei NishiharaDepartment of Radiology, Fujita Health University Hospital, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Masanao KobayashiSchool of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake- cho, Toyoake, Aichi, 470-1192, Japan.
Rei ItoGraduate School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Yoshiki SunadaGraduate School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Tomoya IshidaGraduate School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Haruki IbamotoGraduate School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake-cho, Toyoake, Aichi, 470-1192, Japan.
Shigeki KobayashiSchool of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukake- cho, Toyoake, Aichi, 470-1192, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Partial-angle computed tomography (CT), including CT fluoroscopy and C-arm cone-beam CT systems, plays an important role in image-guided interventions. In these systems, the X-ray tube rotation angle is a critical factor affecting the dose evaluation. However, scans are often performed with partial rotations of approximately 180°-240°, and reliable methods for measuring the actual rotation angle have not been established. In this study, we propose a method for measuring the rotation angle in partial-angle CT scans and improving dose evaluation accuracy by incorporating the measured angles into Monte Carlo simulations. Measurements were performed using CT fluoroscopy and angiography. A CT dose index phantom was placed on the patient table, and metal rods and a real-time dosimeter were inserted into the peripheral holes and center hole, respectively. The rotation angles were identified from the X-ray attenuation caused by the metal rods, and the dose profiles for a single scan were determined by combining measurements acquired with and without the rods. The measured rotation angles and dose profiles were incorporated into Monte Carlo simulations and then validated against measured values. The differences between the displayed and measured rotation angles were 3.4% for CT fluoroscopy and 8.1% for angiography. Compared with the conventional method, the maximum discrepancy in dose evaluation was reduced by 9.0% for CT fluoroscopy and 4.8% for angiography. The proposed method facilitates rotation angle quality assurance in partial-angle CT scans and contributes to appropriate dose management.