Evidence map›Paper›PMID 42100617›Full record

ArticleJSES international2026

Dynamic digital radiography is a valid and reliable alternative to 3 Dimensional registration for scapulohumeral rhythm analysis.

Sameer R Khawaja, Jaden C Hardrick, Zaamin B Hussain, Itaru Kawashima, Joanne Y Zhou, Hayden L Cooke, Krishna N Chopra, Scott A Banks, Michael B Gottschalk, Thomas W Wright and 1 more

Abstract read
In one paragraph

Article in JSES international, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Sameer R KhawajaDepartment of Orthopaedic Surgery, Baylor College of Medicine, Houston, TX, USA.
Jaden C HardrickDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Zaamin B HussainDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Itaru KawashimaDepartment of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA.
Joanne Y ZhouDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Hayden L CookeDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Krishna N ChopraDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Scott A BanksDepartment of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA.
Michael B GottschalkDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.
Thomas W WrightDepartment of Orthopaedic Surgery and Sports Medicine, University of Florida, Gainesville, FL, USA.
Eric R WagnerDepartment of Orthopaedic Surgery, Emory University School of Medicine, Atlanta, GA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Scapulohumeral rhythm (SHR) is a key metric for evaluating shoulder joint function. Current established methods of SHR analysis involve 3-dimensional (3D) to 2-dimensional (2D) registration, which requires significantly greater resources to generate dynamic positioning data of the humerus and scapula. Dynamic digital radiography (DDR) captures pulsed low-dose radiographs in the plane of the scapular elevation to create a cine loop for analysis. This study aimed to establish the most reliable measurement technique by identifying bony landmarks that minimize measurement error and validate manual SHR measurements on DDR against an established 3D to 2D registration technique. Methods: DDRs performed on 22 reverse shoulder arthroplasty shoulders at least 6 months post-operatively were obtained. Manual measurements, including glenohumeral and scapulothoracic angles, were performed on DDRs by 2 authors every 10° of motion from rest to 120° of shoulder elevation. The scapulothoracic angles were measured using either the lateral or medial border of the scapula or scapula spine. Manual measurements were used to calculate SHR across the total range of motion and between various intervals. Results: SHR values were also calculated from a 3D to 2D registration model. Interclass correlations were statistically significant for glenohumeral angles and scapulothoracic angles using the lateral border - 0.989 ( Discussion: SHR measurements on DDR images are a simple and valid technique that can be readily incorporated into clinical workflows, where advanced 3D modeling may be impractical due to resource constraints. DDR provides a novel imaging modality to analyze in vivo shoulder biomechanics with comparable accuracy and validity to that of resource-restricted and time-consuming 3D imaging modalities.

Indexed as

Dynamic digital radiographyGlenohumeralKinematicsScapulohumeral rhythmScapulothoracicShoulder biomechanics

Identifiers

PMID42100617
PMCPMC13147390

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.