Finite element analysis of long proximal femoral bionic nail (PFBN) fixation for femoral shaft fractures combined with ipsilateral femoral neck fractures.

Zixi Fan, Kai Ding, Wei Liu, Biyou Luo, Tailong Shi, Yuqin Zhang, Qi Zhang, Wei Chen

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Zixi Fan *Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.
Kai Ding *Department of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.
Wei Liu *Pharmacy Department, Cangzhou Maternal and Child Health Hospital, Cangzhou, China.
Biyou LuoDepartment of Cardiology, The Third Hospital of Hebei Medical University, Shijiazhuang, China.
Tailong ShiDepartment of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.
Yuqin ZhangDepartment of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.
Qi ZhangDepartment of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.
Wei ChenDepartment of Orthopaedic Surgery, Hebei Medical University Third Hospital, Shijiazhuang, Hebei, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: Femoral reconstruction nails (RN) and three cannulated screws combined with a plate (TCP) are commonly employed for the treatment of ipsilateral femoral neck and shaft fractures (IFNSF). However, these fixation strategies are associated with a considerable incidence of postoperative complications, reflecting the biomechanical challenges of this fracture pattern. Therefore, this study aims to compare the biomechanical performance of a novel long proximal femoral bionic nail (PFBN) with these conventional fixation methods for the treatment of this complex fracture pattern. Methods: Computed tomography (CT) data of the femur were obtained from a healthy adult male volunteer to reconstruct a three-dimensional femoral model using Mimics 21.0 and Geomagic Studio 2013. A combined femoral shaft and ipsilateral femoral neck fracture model was then established in UG 12.0. Three internal fixation constructs-the long PFBN, RN, and TCP-were designed and assembled to simulate surgical fixation. Finite element analysis was subsequently performed using Abaqus 2022 to evaluate stress distribution and displacement characteristics among the three fixation constructs. Results: Under the three loading conditions, the long PFBN exhibited lower or comparable stress and displacement within the fixation constructs. Compared with the TCP construct, the long PFBN showed a more uniform stress distribution. In most loading scenarios, its mechanical performance was comparable to, or slightly better than, that of the RN construct. Analysis of fracture-site micromotion indicated that tangential micromotion at the femoral neck fracture interface in the long PFBN construct was intermediate between that of the RN and TCP constructs. Conclusion: In this finite element analysis, the long PFBN demonstrated relatively favorable biomechanical performance under axial, bending, and torsional loading conditions. These findings may provide preliminary biomechanical insights into the comparative performance of different fixation strategies for this complex fracture pattern.

Indexed as

combined approachfinite element analysisintegrated structureipsilateral femoral neck and shaft fracturesPFBN