Evidence map›Paper›PMID 42099787›Full record

ArticleFrontiers in cardiovascular medicine2026

Wrist-based wearable oscillometric blood pressure monitoring during Ramadan: a comparative study with standard devices.

Eyad Talal Attar

Abstract read
In one paragraph

Article in Frontiers in cardiovascular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

1 author.

Eyad Talal AttarDepartment of Electrical and Computer Engineering, King Abdulaziz University, Jeddah, Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The determination of blood pressure (BP) is crucial for the regulation of cardiovascular health status, particularly under the condition of physiological stress as seen during Ramadan fasting. Conventional BP measurement techniques are, accurate, intermittent and do not reflect the dynamic changes of fasting and rehydration. Wrist-based wearable oscillometric blood pressure monitoring devices, incorporating miniaturized inflatable cuffs, provide a portable and non-invasive approach for assessing BP outside traditional clinical settings. To assess the reliability of a consumer-grade wearable device (Huawei Watch D) for measuring systolic and diastolic blood pressure during Ramadan fasting, and to compare its performance with a validated electronic upper-arm monitor after pre-fast and post-fast conditions (Sahoor and If tar). Methods: A within subject, repeated-measures investigation was performed with 101 healthy fasting subjects (ages 22-70). Each participant recorded BP twice daily during Sahoor and If tar using both the Huawei Watch D and an upper-arm electronic monitor, both are FDA-approved. Statistical methods comprised paired t tests, as well as Pearson correlations and Bland-Altman plots. To evaluate prediction accuracy and discover subgroups, we also used machine learning approaches (linear regression and K-means clustering). Results: Compared with the electronic upper-arm monitor, the Huawei Watch D demonstrated minimal mean bias for both systolic and diastolic blood pressure (SBP: +0.9 to +1.4 mmHg; DBP: -0.6 to -0.2 mmHg). However, SBP exhibited wide limits of agreement (±18-21 mmHg), whereas DBP showed narrower dispersion (±11-13 mmHg). Machine-learning models achieved moderate prediction accuracy for DBP (MAE ≈ 4.3-6.1 mmHg, R² up to 0.74), while SBP prediction remained less accurate (MAE ≈ 6.5-8.9 mmHg, R² up to 0.64).However, SBP exhibited wide limits of agreement (±20 mmHg), limiting diagnostic interchangeability. DBP showed narrower error dispersion, supporting the use of wearable devices for trend monitoring and screening rather than clinical diagnosis. Conclusions: Smartwatch BP estimates are associated with standard devices, however, individual differences are considerable and therefore do not allow for diagnostic interchangeability. Wearables, such as the Huawei Watch D, provide the interesting data on the BP trend during fasting and rehydration, especially in diastolic pressure. These devices may assist with culturally appropriate monitoring and early identification of BP abnormalities however are in need of validation in a clinical context.

Indexed as

blood pressurecardiovascular healthcircadian variationdiastolicHuawei watch dnon-invasive measurementphysiological monitoringRamadan fasting

Identifiers

PMID42099787
PMCPMC13143989

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.