ArticleFrontiers in cardiovascular medicine2026
Long-term follow-up results of percutaneous closure of atrial septal defect with a novel biodegradable poly-L-lactic acid device in pediatrics: data from a prospective, single-center trial.
Article in Frontiers in cardiovascular medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: The poly-L-lactic acid (PLLA) occluder is a novel, fully biodegradable device designed for percutaneous atrial septal defect (ASD) closure. First-in-human studies have demonstrated its preliminary safety and efficacy. Objective: This study aimed to evaluate the 5-year safety and efficacy of the PLLA device for percutaneous ASD closure in a single-center pediatric cohort. Methods: From May 2018 to August 2019, 36 patients with clinically significant ASD were enrolled and underwent percutaneous closure using the PLLA device. Follow-up assessments were conducted at discharge and at 1, 3, 6, 12, 24, 36, 48, and 60 months post-implantation. The primary endpoint was a composite of clinical success, defined as successful closure and absence of major complications at the 60-month follow-up. Results: Successful device implantation was achieved in 35 of 36 patients (97.2%). All of the 35 patients completed the 5-year follow-up. The closure success rate and complete closure rate at 5 years were 85.7% (30/35) and 77.1% (27/35), respectively. Clinically significant residual leaks at 5- year visit were observed in 5 patients (14.3%). A total of 5 complications (14.3%) occurred, consisting of cardiac arrhythmia ( Conclusion: Long-term follow-up confirms a favorable safety profile for percutaneous ASD closure using the PLLA device, with a cumulative complication rate of 14.2% and no major adverse events reported over 5 years. However, the incidence of residual leaks remains noteworthy, suggesting suboptimal long-term efficacy in pediatric patients and in cases involving large defects.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.