ArticleAnalytical and bioanalytical chemistry2026
Combination of magnetic bead extraction and LC-MS/MS detection for the detection of saliva cortisol.
Article in Analytical and bioanalytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Salivary cortisol is an important biomarker for the assessment of stress-related disorders and endocrine function. Due to the noninvasive and convenient nature of saliva sampling, it has considerable potential for clinical application. However, the low concentration of cortisol in saliva, typically at the nanograms-per-milliliter level, together with the complexity of the salivary matrix, poses substantial challenges to analytical sensitivity and selectivity. In this study, an analytical method for salivary cortisol determination was developed based on immunomagnetic bead enrichment and purification coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Cortisol monoclonal antibodies were conjugated to carboxyl-modified nanomagnetic beads, and the target analyte was extracted and purified through immunoaffinity adsorption followed by ethanol elution. The method exhibited good linearity over the ranges of 0.10-1.00 ng/mL and 1.00-20.00 ng/mL, with a limit of detection (LOD) of 0.04 ng/mL and a lower limit of quantification (LLOQ) of 0.10 ng/mL. The method also showed satisfactory accuracy, with spiked recoveries ranging from 80% to 110%. In addition, salivary cortisol concentrations showed a strong positive correlation with serum cortisol concentrations (Pearson correlation coefficient, r = 0.91636). These results indicate that the proposed method provides a sensitive, selective, and reliable approach for salivary cortisol analysis and shows promise for clinical application.
Indexed as
Identifiers
42098506What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.