ArticleJournal of biomechanical engineering2026
Multiscale Architecture Governs Stability in Suction-Actuated Variable Stiffness Catheters.
Article in Journal of biomechanical engineering, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors.
Funding
Abstract
Endovascular procedures require devices with widely varying mechanical properties: flexibility for navigating tortuous vessels, and rigidity for stable therapeutic delivery. Suction-actuated variable stiffness sheaths attempt to address this challenge by incorporating axial wire string arrays that couple mechanically under suction to increase flexural rigidity. However, prototype devices achieve stiffening ratios well below theoretical predictions, suggesting that string array positioning and interlayer mechanics require investigation. We therefore investigated whether interweaving expanded polytetrafluoroethylene (PTFE) tape within the string array can enhance flexural rigidity modulation and improve bending uniformity along the catheter length. Prototypes with varying PTFE wrap configurations were fabricated and evaluated using three complementary approaches. First, flexural testing revealed that flexural rigidity in the actuated and unactuated states was largely unaffected by wrapping for small deformations. Second, curvature stability testing revealed that deformation through acute simulated vascular bends was higher than expected due to two failure mechanisms: slip, in which string arrays migrate after overcoming wrap-imposed friction, and buckling, in which arrays become locally pinned and deflect against the outer lumen. Finally, a mathematical model characterized stability limits as functions of the wrapping architecture and device mechanical properties, revealing criteria for which device performance improved. Results suggest design principles for intracatheter wrapping that can narrow the gap between theoretical and achieved flexural rigidity ratios, potentially contributing to the development of endovascular devices capable of single-sheath navigation and intervention.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.