Evidence map›Paper›PMID 42095338›Full record

ArticleNMR in biomedicine2026

Reducing Variability in Deep Gray Matter QSM Using Differential ROI Referencing: A Phantom and In Vivo Evaluation.

Tae Hyun Hwang, Gawon Lee, Myung Kyun Woo, Se-Hong Oh

Abstract read
In one paragraph

Article in NMR in biomedicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tae Hyun HwangAIRS Medical, Seoul, Republic of Korea.
Gawon LeeDepartment of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Republic of Korea.ORCID https://orcid.org/0000-0002-9955-1974
Myung Kyun WooDepartment of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Republic of Korea.
Se-Hong OhDepartment of Biomedical Engineering, Hankuk University of Foreign Studies, Yongin, Republic of Korea.ORCID https://orcid.org/0000-0001-9771-8382

Funding

Hankuk University of Foreign Studies Research FundMSIT, South Korea RS-2026-25486260National Research Foundation of Korea (NRF)
6 · The paper itself

Abstract

Quantitative susceptibility mapping (QSM) measures the intrinsic magnetic susceptibility of tissues. Because susceptibility values are inherently relative rather than absolute, referencing to a region of interest (ROI) is commonly employed to mitigate intersubject and acquisition-related variability. To validate the feasibility and robustness of a differential ROI reference method in QSM using both digital phantom and in vivo data, particularly for deep gray matter susceptibility analysis. In the digital phantom study, susceptibility values in the caudate nucleus were assessed with and without differential referencing across various simulation conditions (slab widths, brain mask erosion levels, air susceptibility). In the in vivo study, susceptibility differences between 16 patients with Parkinson's disease (PD) and 16 controls were compared across multiple deep gray matter ROIs under variable acquisition parameters. A one-way ANOVA statistical test was used in the in vivo study with multiple-comparison correction via the Benjamini-Hochberg false discovery rate (FDR-BH), with significance set at p < 0.05. In this study, "accuracy" refers specifically to the phantom study where ground-truth susceptibility values are known. In vivo, where such ground truth is unavailable, "robustness" and "group-discrimination sensitivity" are used as surrogate indicators of accuracy. Robustness was evaluated by the consistency of susceptibility differences across varying acquisition parameters, whereas group-discrimination sensitivity was evaluated by the ability to detect disease-related group differences between PD patients and controls. In the digital phantom study, the proposed method demonstrated stable susceptibility estimates across all conditions, with minimal deviation from true values when referencing anatomically adjacent ROIs. In the in vivo study, referenced susceptibility values (e.g., substantia nigra minus putamen) yielded consistent and significant group differences across acquisition scenarios, whereas unreferenced values were more variable. The differential ROI reference method reduces susceptibility variability associated with acquisition and processing factors. This approach may offer a practical and pathology-resilient referencing alternative for deep brain analysis in neurodegenerative diseases.

Indexed as

Gray MatterMagnetic Resonance ImagingPhantoms, ImagingAgedFemaleHumansMaleMiddle AgedParkinson DiseaseReproducibility of Resultsbrain QSMmagnetic resonance imagingmagnetic susceptibility mappingParkinson's diseaseQSMreference ROIsubstantia nigrasusceptibility

Identifiers

PMID42095338
PMCPMC13150806

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.