Evidence map›Paper›PMID 42091667›Full record

ArticleScientific reports2026

Comparison of hip and knee range of motion measurements using Azure Kinect and a digital goniometer in elite female weightlifters.

Bülent Işik, Kenan Erdaği, Serkan Örücü, Erkan Özbay, Usame Ömer Osmanoğlu

Abstract readComparative Study
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Bülent IşikDepartments of Physiology, Faculty of Medicine School, University of Karamanoğlu Mehmetbey, 70200, Karaman, Turkey. bulentisik@kmu.edu.tr.ORCID http://orcid.org/0000-0001-8753-8302
Kenan ErdağiDepartments of Physical Education and Sports, Ahmet Keleşoğlu Faculty of Education, Necmettin Erbakan University, 42090, Konya, Turkey.ORCID http://orcid.org/0000-0002-2338-6546
Serkan ÖrücüVocational School of Technical Sciences, Computer Technologies Program, Karamanoğlu Mehmetbey University, 70200, Karaman, Turkey.ORCID http://orcid.org/0000-0001-9905-2908
Erkan ÖzbayKaramanoğlu Mehmetbey University Vocational School of Health, 70200, Karaman, Turkey.ORCID http://orcid.org/0000-0002-8781-3877
Usame Ömer OsmanoğluDepartments of Biostatistics, Medical School, University of Karamanoğlu Mehmetbey, 70200, Karaman, Turkey.ORCID http://orcid.org/0000-0002-1198-2447

Funding

Karamanoğlu Mehmetbey Üniversitesi 14-M-24Karamanoğlu Mehmetbey Üniversitesi 51-M-24
6 · The paper itself

Abstract

Accurate assessment of joint range of motion (ROM) is essential in both clinical and athletic contexts for monitoring mobility, guiding rehabilitation, and optimizing performance. Traditional tools such as goniometers are widely used but limited by operator dependency and static measurement constraints. Depth-sensing technologies offer a markerless alternative that may enhance practicality in field-based settings. This study examined the validity and reliability of the Microsoft Azure Kinect system compared with a digital goniometer for assessing hip and knee ROM in 30 elite female weightlifters from the Turkish National Team. Participants performed hip abduction, adduction, flexion, extension, and knee flexion, each measured using both tools. Agreement between systems was assessed using Pearson's correlations, intraclass correlation coefficients [ICC (3,1)], and Bland-Altman analyses. No significant differences were found between methods (p > 0.05), with strong correlations (r = 0.974-0.997) and high intraclass correlation coefficients (ICC = 0.994-0.998), indicating excellent consistency. Bland-Altman analyses showed minimal bias and narrow limits of agreement. These findings support the Azure Kinect as a valid and reliable tool for lower-extremity ROM assessment and a viable alternative to traditional goniometers in field applications.

Indexed as

Arthrometry, ArticularHip JointKnee JointRange of Motion, ArticularAdultFemaleHumansReproducibility of ResultsYoung AdultAzure KinectDepth sensor-based motion analysisElite female athletesHip joint kinematicsKnee joint range of motion

Identifiers

PMID42091667
PMCPMC13338057

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.