ArticleScientific reports2026
A compact variable stiffness joint for compliant robotics enabled by torsion-spring mean-diameter variation.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
For robotic applications requiring compliance and safety in rehabilitation training, physical human-robot collaboration, and unstructured environments, this study proposes a variable-stiffness joint design method, termed TSDV, based on the mean-coil-diameter variation mechanism of a torsion spring. First, the variation of the mean coil diameter of a cylindrical torsion spring with joint deflection angle is analyzed. On this basis, a structural scheme for stiffness modulation is proposed by constraining the inward contraction of the spring inner diameter. The joint mainly comprises a torsion spring, an internal slotted sleeve, and a ball-guiding sleeve, and features a compact architecture, a wide stiffness regulation range, coaxial alignment with the robot joint axis, and both passive and active stiffness modulation modes. Subsequently, a nonlinear stiffness model of the variable-stiffness joint system is established using an energy-based method, and the validity of the theoretical model is verified through numerical simulations and finite-element analysis. The results show that both the output torque and the joint stiffness exhibit tunable nonlinear characteristics with respect to the deflection angle and regulation parameters. Finally, experiments are conducted on a TSDV prototype. The experimental results demonstrate that, under motor actuation, the proposed joint can achieve both passive and active stiffness regulation. When the deflection angle reaches 1.2 rad, the output torque range increases from 0 to 3.8 Nm to 0-9.2 Nm. Moreover, when the slotted sleeve fully suppresses the variation of the torsion spring inner diameter, the joint exhibits a locking function and transitions into a rigid joint. These findings indicate that the proposed variable-stiffness joint offers a compact structure, a large stiffness regulation range, and high control resolution, thereby providing a new approach for safe interaction and compliant actuation in robotic systems.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.