Evidence map›Paper›PMID 42085583›Full record

ArticleSICOT-J2026

Development and measurement of elbow and knee joints using an electro-goniometer in healthy subjects: A preliminary study.

Sasipa Buranapuntalug, Nuchrada Chaitrakul, Pollapat Liamtragoolpanich, Chusak Thanawattano, Chatchai Buekban, Kornanong Yuenyongchaiwat

Abstract read
In one paragraph

Article in SICOT-J, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sasipa BuranapuntalugPhysiotherapy Department, Faculty of Allied Health Sciences, Thammasat University, Pathumthani, Thailand - Thammasat University Research Unit for Physical Therapy in Respiratory and Cardiovascular Systems, Thammasat University, Pathumthani, Thailand.
Nuchrada ChaitrakulPhysiotherapy Department, Faculty of Allied Health Sciences, Thammasat University, Pathumthani, Thailand.
Pollapat LiamtragoolpanichPhysiotherapy Department, Faculty of Allied Health Sciences, Thammasat University, Pathumthani, Thailand.
Chusak ThanawattanoBiomedical Electronics and Systems Research Team, Assistive Technology and Medical Devices Research Group, National Electronics and Computer Technology Center (NECTEC) 12120, Pathum Thani, Thailand.
Chatchai BuekbanBiomedical Electronics and Systems Research Team, Assistive Technology and Medical Devices Research Group, National Electronics and Computer Technology Center (NECTEC) 12120, Pathum Thani, Thailand.
Kornanong YuenyongchaiwatPhysiotherapy Department, Faculty of Allied Health Sciences, Thammasat University, Pathumthani, Thailand - Thammasat University Research Unit for Physical Therapy in Respiratory and Cardiovascular Systems, Thammasat University, Pathumthani, Thailand.ORCID 0000-0002-2997-4904

Funding

Faculty of Allied Health Sciences AHSRS 1/2569
6 · The paper itself

Abstract

introductionRange of Motion (ROM) assessment is a critical baseline metric for diagnosis, treatment monitoring, and rehabilitation goal setting. It significantly impacts patient well-being, aligning with Sustainable Development Goal 3 (SDG 3). However, the universal goniometer (UG), presents limitations regarding accuracy and practical efficiency in clinical settings. Therefore, this study aimed to determine the concurrent validity of an electronic goniometer named Goniwear compared to the UG for measuring elbow and knee angles.

methodsThe validity of Goniwear involved 40 healthy volunteers stratified by age (20-39 and 40-59 years) and sex. Simultaneous active and passive ROM measurements were conducted three times using both UG and on flexion and extension of the elbow and knee joints. Data were analyzed using the intraclass correlation coefficients (ICC), which were calculated using a two-way random-effects model, and the Bland-Altman method was used to determine the limits of agreement (LoA) between the UG and Goniwear.

resultsReliability between the two instruments ranged from poor to excellent, depending on the joint and movement type. Elbow flexion and extension demonstrated consistently good to excellent reliability in both active and passive conditions (ICC = 0.84-0.91), with minimal bias and relatively narrow LoA. Knee flexion and extension showed poor to moderate reliability (ICC = 0.44-0.55), particularly for extension, accompanied by a wide LoA.

conclusionAgreement between the UG and Goniwear varies across joints and movement conditions. While the instruments appear interchangeable for elbow movements, caution is warranted when interpreting knee ROM due to greater measurement variability. DISCUSSION: The Goniwear demonstrates high validity for single-axis joints with fixed pivot points, suggesting strong potential for clinical application in specific contexts.

trial registrationThe Thai Clinical Trials Registry is TCTR20251120001.

Indexed as

Electronic GoniometerGoniometerMovementRange of Motion

Identifiers

PMID42085583
PMCPMC13143208

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.