Evidence map›Paper›PMID 42084189›Full record

ArticleSkin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI)2026

Choosing the Right Tewl Device: A Comparison of Inter- and Intra-Device Reliability of the Vapometer and Dermalab across Measurement Ranges.

Tanja Klotz, Suzanne Edwards, Guy Maddern, Marcus Wagstaff

Abstract readComparative Study
In one paragraph

Article in Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging (ISSI), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Tanja KlotzFaculty of Health and Medical Sciences, Adelaide University, Adelaide, South Australia, Australia.ORCID https://orcid.org/0000-0001-8466-4821
Suzanne EdwardsSchool of Public Health, Adelaide University, Adelaide, South Australia, Australia.
Guy MaddernFaculty of Health and Medical Sciences, Adelaide University, Adelaide, South Australia, Australia.
Marcus WagstaffDepartment of Plastic and Reconstructive Surgery, Royal Adelaide Hospital, Adelaide, South Australia, Australia.

Funding

Australian Government Research Training Program Scholarship
6 · The paper itself

Abstract

backgroundMeasurement of transepidermal water loss (TEWL) is widely used to evaluate skin barrier function. MATERIALS AND

methodsThis study compared two devices-the DermaLab (DL) TEWL probe and the VapoMeter (VM) - from data collected across three studies to measure TEWL in scarred and normal skin. Each site was measured three times per device, alternating devices to allow vapor clearance. Inter-device reliability was assessed from 1,617 paired locations, each averaged from the three readings. Intra-observer reliability was able to be determined from a dataset of 1,628 DL and 1,635 VM measurements.

resultsData were stratified into low, medium, and high TEWL ranges based on measurement distribution and observations. Overall inter-device reliability was 'good' but varied by range: 'poor' in low, 'excellent' in medium, and 'moderate' in high TEWL ranges. In the medium range, the VM reported nearly twice the TEWL values compared to the DL, while in the high range, it read approximately 34% higher.

conclusionsBoth devices showed excellent intra-observer reliability overall. However, in the low TEWL range, the DL exhibited 'moderate' reliability, whereas the VM showed slightly better, 'good' reliability. Differences in chamber architecture-semiopen for the DermaLab and closed for the VM-appear to drive the observed variability in measurement reliability across TEWL ranges. Analysis of this large dataset indicates that the VM likely approaches saturation at the categorized 'high' TEWL values, constraining its accuracy, whereas the DermaLab exhibits reduced measurement stability at low TEWL levels, limiting its applicability under those conditions. Targeted methodological work is needed to refine DL performance in the lowTEWL regime and to more precisely define the upper operational limit of the VM.

Indexed as

Water Loss, InsensibleEquipment DesignEquipment Failure AnalysisFemaleHumansObserver VariationReproducibility of ResultsSensitivity and SpecificitySkin Physiological Phenomenaevaporimeterinsensible water lossscarskintransepidermal water loss

Identifiers

PMID42084189
PMCPMC13140847

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.