Postapproval Study Outcomes of Muscular Ventricular Septal Defect Closure With the Amplatzer Muscular VSD Occluder.
Article in Circulation. Cardiovascular interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT00647387 (Closure of Muscular Ventricular Septal Defects), which is not on this map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Closure of Muscular Ventricular Septal Defects (VSDs) With the AMPLATZER Muscular VSD (MuVSD) Occluder - Post Approval Study
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
11 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe Amplatzer Muscular Ventricular Septal Defect (VSD) Occluder (Abbott Structural Heart, Plymouth, MN) was approved by the US Food and Drug Administration in 2007. As a condition of approval, a postapproval study was required to further evaluate its safety and effectiveness. This study reports the clinical outcomes from the postapproval study over 5 years of follow-up.
methodsPatients with complex congenital muscular VSDs at high risk for surgical closure were enrolled between May 2008 and February 2020 in the United States and Canada. The primary effectiveness end points were technical implant success, acute procedure shunt-closure success, and 1-year shunt-closure success. The primary safety end point was the proportion of patients with any serious adverse event within 12 months of the procedure.
resultsA total of 92 patients (median age, 2 years; 50 females) were enrolled in the study. Technical implant success was achieved in 93.8% of patients, and acute shunt-closure success was achieved in 78.0%. Successful shunt closure at 1-year was 94.4% and increased to >98% between 2 and 5 years. Within 12 months of the procedure, all-cause serious adverse events occurred in 47 of the 90 (52.2%) patients which included 7 device-related and 23 procedure-related serious adverse events. Between 1 and 5 years, there was 1 additional device- and procedure-related serious adverse event.
conclusionsThis postapproval study demonstrates that transcatheter muscular VSD closure with the Amplatzer Muscular VSD Occluder is a safe and effective therapy for the treatment of complex congenital muscular VSDs in patients who are at high-risk for surgical closure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT00647387.