Evidence map›Paper›PMID 42082886›Full record

ArticleInternational journal of implant dentistry2026

Effect of cold atmospheric pressure plasma on wettability of implant prosthetic materials: an in-vitro study.

Moataz Bayadse, Leonie Grander, Lisa Steiner, Samir Abou-Ayash, Stefan Wentaschek

Abstract read
In one paragraph

Article in International journal of implant dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Moataz BayadseDepartment of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany. moataz.bayadse@unimedizin-mainz.de.
Leonie GranderDepartment of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany. leonie.grander@unimedizin-mainz.de.
Lisa SteinerDepartment of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany. lisa.steiner@unimedizin-mainz.de.
Samir Abou-AyashDepartment of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
Stefan WentaschekDepartment of Prosthodontics and Material Science, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany. stefan.wentaschek@unimedizin-mainz.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeSurface wettability is a key factor in bonding of dental materials. The aim of the present study was to investigate the influence of different exposure times of cold atmospheric pressure plasma at constant power on the surface wettability of various dental materials employed in implantology, using the "Piezo-Brush

methodsSeventy-five standardized specimens made of titanium alloy, zirconia, lithium disilicate and polymer-infiltrated hybrid ceramic network were manufactured and polished. Specimens of each material were divided into 5 groups (each n = 15). Four groups were cold atmospheric pressure plasma treated for 5, 10, 20, 30 s and compared to the untreated control group. Surface wettability was assessed by measuring the contact angle of distilled water using a goniometer. Statistical analysis was performed using one-way ANOVA.

resultsThe mean contact angle was significantly reduced by 60-80% after 5 s of cold atmospheric pressure plasma treatment for all investigated materials (p < 0.001). Prolonged cold atmospheric pressure plasma exposure resulted in further reduction in mean contact angle values for titanium at each additional treatment duration (p < 0.001), whereas for lithium disilicate a reduction was observed only up to 10 s. For zirconia and polymer-infiltrated hybrid ceramic network, no further reduction in contact angle was observed beyond 5 s of cold atmospheric pressure plasma treatment.

conclusionCold atmospheric pressure plasma treatment significantly increases surface wettability after short exposure times. Within the limitations of this study, these findings may indicate a potential improvement in adhesion behavior. However, under the plasma parameters applied, extending treatment beyond 5 s for zirconia and polymer-infiltrated hybrid ceramic network or beyond 10 s for titanium and lithium disilicate did not result in further reduction of contact angle. The clinical relevance of these findings requires further investigation.

Indexed as

Dental ImplantsDental MaterialsPlasma GasesWettabilityAtmospheric PressureDental PorcelainIn Vitro TechniquesMaterials TestingSurface PropertiesTitaniumZirconiumDental ImplantsDental MaterialsDental Porcelainlithia disilicatePlasma GasesTitaniumZirconiumzirconium oxideAbutment crownCAD-CAMCold atmospheric pressure plasmaContact angleSurface treatmentTitaniumWettabilityZirconia

Identifiers

PMID42082886
PMCPMC13139521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390