Adaptive long short term memory-PI based control for load frequency regulation in electric vehicle integrated two area power systems.

Sandip Kumar Das, Sarat Chandra Swain, Byamakesh Nayak, Ritesh Dash, Futa Osumanu, Bhabasis Mohapatra, Seif Al Bustanji, Oleksandr Rubanenko

Abstract read
In one paragraph

Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Sandip Kumar DasSchool of Electrical Engineering, KIIT University, Bhubaneswar, India.
Sarat Chandra SwainSchool of Electrical Engineering, KIIT University, Bhubaneswar, India.
Byamakesh NayakSchool of Electrical Engineering, KIIT University, Bhubaneswar, India.
Ritesh DashSchool of Electrical and Electronics Engineering, REVA University, Bengaluru, India.
Futa OsumanuDepartment of Electrical/Electronic Engineering, Accra Technical University, Accra, Ghana.
Bhabasis MohapatraDepartment of Electrical Engineering, ITER, Siksha 'O' Anusandhan (Deemed to be University), Bhubaneswar, Odisha, 751030, India. bhabasismohapatra@soa.ac.in.
Seif Al BustanjiFaculty of Technical Education, Hourani Center for Applied Scientific Research, Al-Ahliyya Amman University, Amman, Jordan.
Oleksandr RubanenkoDepartment of Power Plants and System, Vinnytsia National Technical University, Vinnytsia, 21000, Ukraine. rubanenko.o.y@vntu.edu.ua.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The growing penetration of electric vehicles (EVs) and renewable energy sources has introduced significant nonlinear and stochastic disturbances in modern power systems, posing major challenges to conventional load frequency control (LFC) strategies. To address these issues, a Long Short-Term Memory-based Proportional Integral (LSTM-PI) controller is proposed to enable adaptive frequency regulation in a two-area EV-integrated system. The LSTM network dynamically tunes the proportional and integral gains in response to temporal variations in frequency and tie-line states. The learning module is trained using an Integral of Time weighted Absolute Error (ITAE) objective. Practical non-linearities such as governor deadband, generation-rate constraints, valve saturation, and EV state-of-charge limits are incorporated into both the training dataset and the online control evaluation. A constrained Model Predictive Control (CMPC-PI) is developed as a modern benchmark to compare the proposed technique under identical sampling rates and actuator limits. The proposed method shows better performance under dynamic conditions. Statistical performance analysis has been carried out through 30 runs of Monte Carlo analysis with a mean of 95% confidence intervals. Stability analysis under time-varying gains is supported by a bounded-gain Lyapunov Framework and a delay-margin analysis that addresses sensing and actuation delays. The result analysis confirms that the LSTM-PI controller provides a scalable intelligent solution for modern EV-integrated smart grid frequency regulation. The proposed intelligent adaptive controller provides a scalable, low-complexity, and stability-assured solution for robust load-frequency regulation in nonlinear, EV-integrated smart power grids.

Indexed as

Adaptive controlElectric vehicle integrationIntelligent controllerLoad frequency controlLong short-term memoryLyapunov stabilityMonte Carlo analysisNonlinear dynamicsSmart gridTwo-area power system