ArticleEJNMMI physics2026
Advancements in DOI-capable TOF-PET modules using a multi-channel high-frequency readout.
Article in EJNMMI physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe achievement of excellent coincidence time resolution has become an essential objective in time-of-flight positron emission tomography (TOF-PET) in order to improve the signal-to-noise ratio and the quality of the reconstructed image. Moreover, to achieve a high level of spatial resolution while maintaining good sensitivity with the use of long scintillators, the impact of the gamma-ray depth of interaction (DOI) must be mitigated.
methodsTo address these challenges, a matrix of sixteen 20 mm-long LYSO:Ce scintillators with depolished lateral surfaces is used, coupled to a light guide that enables light sharing within the matrix. This configuration allows for the determination of the gamma-ray DOI and the correction of its timing bias. For this light-sharing method to work, readout integration in a multi-channel scheme is required. This is achieved using a sixteen-channel low-noise, low-power, high-frequency development circuit board. This high-frequency circuit also provides a solution to enhance the time resolution by enabling a lower leading-edge threshold for the detection of the earliest photons produced with high precision.
resultsThe DOI-capable module achieves a DOI resolution of 2.2 ± 0.2 mm full-width-at-half-maximum (FWHM) and a CTR of 133 ± 2 ps FWHM after DOI correction on the central crystals. For comparison, a standard module consisting of sixteen polished crystals and no back light guide achieves a CTR of 130 ± 2 ps FWHM.
conclusionsUsing 20 mm-long LYSO:Ce crystals and this high-frequency electronics, the DOI-capable module delivers excellent timing and energy resolution. In addition to providing time resolution comparable to that of the standard module, it also allows DOI encoding with a resolution of nearly 2 mm FWHM.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.