Optimizing point-of-care ultrasound video acquisition for probabilistic multi-task heart failure detection.

Armin Saadat, Nima Hashemi, Bahar Khodabakhshian, Michael Y Tsang, Christina Luong, Teresa S M Tsang, Purang Abolmaesumi

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Armin SaadatDepartment of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada. arminsdt@ece.ubc.ca.ORCID http://orcid.org/0009-0005-8322-1216
Nima HashemiDepartment of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada.
Bahar KhodabakhshianDepartment of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada.
Michael Y TsangVancouver General Hospital, Vancouver, BC, Canada.
Christina LuongVancouver General Hospital, Vancouver, BC, Canada.
Teresa S M Tsang *Vancouver General Hospital, Vancouver, BC, Canada.
Purang Abolmaesumi *Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada. purang@ece.ubc.ca.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeEchocardiography with point-of-care ultrasound (POCUS) must support clinical decision-making under tight bedside time and operator-effort constraints. We introduce a personalized, budget-constrained data acquisition strategy in which a reinforcement learning agent, given a partially observed multi-view study, selects the next view to acquire or terminates acquisition to support heart failure (HF) assessment. Upon termination, a diagnostic model jointly predicts aortic stenosis (AS) severity and left ventricular ejection fraction (LVEF), two key HF biomarkers, and outputs calibrated uncertainty, enabling an explicit trade-off between diagnostic performance and acquisition cost.

methodsWe model bedside POCUS as a sequential, cost-constrained acquisition problem in which an RL agent retrospectively selects among five predefined standard views, each represented by one clip with equal acquisition cost, or terminates acquisition. Upon termination, a shared multi-view transformer performs multi-task inference with two heads, ordinal AS classification and LVEF regression, and outputs Gaussian predictive distributions yielding ordinal probabilities over AS classes and EF thresholds. These probabilities drive a reward that balances expected diagnostic benefit against acquisition cost (e.g., number of acquired views), producing patient-specific acquisition pathways rather than a fixed protocol. The video selector is trained with online RL, updating on-policy in a partial-observation simulator built from complete multi-view POCUS studies.

resultsThe dataset comprises 12,180 patient-level studies, split into training/validation/test sets (70/15/15). On the 1820 test studies, our method matches full-study performance while using

conclusionIn this constrained retrospective setting, patient-tailored view selection preserves decision quality while reducing the number of acquired views, supporting adaptive acquisition policies. The framework is extensible to additional cardiac endpoints and warrants prospective evaluation in live bedside POCUS. The code is available at https://github.com/Armin-Saadat/Double-Precise.

Indexed as

EchocardiographyHeart FailurePoint-of-Care SystemsVideo RecordingAortic Valve StenosisHumansReinforcement Machine LearningRetrospective StudiesStroke VolumeActive video acquisitionAortic stenosisBudget-constrained echocardiographyEjection fractionMulti-task learningPoint-of-care ultrasoundReinforcement learning