Evidence map›Paper›PMID 42079803›Full record

ArticleCJC pediatric and congenital heart disease2026

The Initial Middle Eastern Experience With the Alterra Adaptive Pre-Stent: Single-Center Outcomes From Saudi Arabia.

Mohamed Al Nasef, Bandar Al Shehri, Khalid Al Naji, Ahmed Al Zahrani, Merna Atiyah, Omar Abdulaziz Almohizy, Saria Mansour Ahmed, Khalid Al Najashi

Abstract read
In one paragraph

Article in CJC pediatric and congenital heart disease, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Mohamed Al NasefPediatric Cardiology and Adult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Bandar Al ShehriAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Khalid Al NajiAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Ahmed Al ZahraniAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Merna AtiyahAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Omar Abdulaziz AlmohizyAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Saria Mansour AhmedAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.
Khalid Al NajashiAdult Congenital Heart Disease, Prince Sultan Cardiac Center, Riyadh, Kingdom of Saudi Arabia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The Alterra Adaptive Pre-Stent, used with the Edwards SAPIEN 3 valve, offers a novel transcatheter option for patients with severely dilated right ventricular outflow tracts (RVOTs) previously unsuitable for conventional transcatheter pulmonary valve replacement (TPVR). No prior experience with this system has been reported from the Middle East. Methods: We report the first Middle Eastern experience with the Alterra Adaptive Pre-Stent from a high-volume congenital heart center. A retrospective, single-center analysis was performed at Prince Sultan Cardiac Center (Riyadh, Saudi Arabia). Between April and July 2025, a total of 10 patients with native (after balloon valvuloplasty) or surgically patched RVOTs underwent TPVR using the Alterra Pre-Stent and Edwards SAPIEN 3 valve. Patient selection, procedural data, and early clinical outcomes were reviewed. Results: All 10 patients (mean age: 30 ± 7.1 years; range: 15-40 years) underwent successful implantation. The mean weight was 66.4 ± 22.7 kg (range: 35-103 kg), and 30% (n = 3) were male. Procedural success was 100%, with accurate device positioning and no significant residual gradient or pulmonary regurgitation. No major complications-including valve embolization, coronary compression, or surgical conversion-occurred. At a median follow-up of 31 days (range: 10-43 days), all patients remained clinically stable with improved functional status. Conclusions: This is the first reported experience of the Alterra Adaptive Pre-Stent in the Middle East. Early results demonstrate that the device is safe, technically feasible, and effective in selected patients with complex RVOT anatomies, potentially broadening TPVR applicability in the region.

Indexed as

Alterra prestentpercutaneous pulmonary valve implantationTetrology of Fallot

Identifiers

PMID42079803
PMCPMC13129532

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.