ArticleJMIR neurotechnology2026
Diagnostic Accuracy of GPT-4 With Vision in Neuroradiology Board-Style Exam Questions: Cross-Sectional Case-Based Study.
Article in JMIR neurotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Multimodal artificial intelligence systems combining text and image analysis represent a paradigm shift in clinical decision support. While GPT-4 with Vision (GPT-4V) has shown promise in medical imaging interpretation, existing studies report inconsistent performance (16%-80% accuracy) across radiological subspecialties. Critical knowledge gaps persist regarding GPT-4V's capability to integrate clinical history with imaging findings in complex neuroradiology scenarios, and fundamental questions remain about whether the model appropriately balances visual and textual information sources when formulating diagnoses. Furthermore, documented artificial intelligence hallucination rates of 35.5% to 63% in radiology applications raise urgent safety concerns, yet the relationship between modality utilization patterns and diagnostic accuracy remains unexplored. Objective: This study aims to evaluate GPT-4V's diagnostic accuracy on expert-validated neuroradiology board-style examination questions and to examine the model's self-reported reliance on imaging versus clinical text data when making diagnostic decisions. A secondary objective was to examine whether self-characterized modality utilization patterns differed systematically between correct and incorrect diagnoses, potentially identifying specific failure modes requiring targeted mitigation strategies. Methods: This cross-sectional study evaluated GPT-4V using 29 neuroradiology cases from the RSNA (Radiological Society of North America) Case Collection, covering adult brain and central nervous system pathologies imaged via computed tomography or magnetic resonance imaging. The cases were authored by board-certified radiologists. GPT-4V was accessed via ChatGPT Plus (July 2024) with standardized prompts selecting 1 answer from 4 options, providing diagnostic rationale, and quantifying the percentage contributions of image versus text data. Binary scoring assessed diagnostic performance (correct=1, incorrect=0). Statistical analysis included Wilson score CIs, a binomial test comparing accuracy to chance, and a 2-tailed Results: GPT-4V correctly diagnosed 22 of 29 cases (76% accuracy, 95% CI 57.9%-87.8%), significantly exceeding the chance performance of 25% ( Conclusions: The 76% accuracy substantially exceeds prior GPT-4V radiology studies (43%), demonstrating that focused domain application with structured prompting enhances performance. Incorrect diagnoses are associated with higher self-reported visual reliance, suggesting a potential failure mode warranting experimental validation. This pattern identifies a potentially actionable signal for quality assurance systems. Clinical deployment should remain restricted to supervised educational applications with mandatory radiologist oversight until balanced context-aware integration is validated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.