Evidence map›Paper›PMID 42078007›Full record

ArticleRadiology advances2026

Improved prostate diffusion imaging using deep learning denoising and phase correction with ultra-high-density coil array.

Sherry S Huang, Xinzeng Wang, Patricia Lan, Milica Medved, Nurullah Kaya, Clyve K Follante, Yunjeong Stickle, Jonathan Taylor, Ambereen Yousuf, Roger Engelmann and 4 more

Abstract read
In one paragraph

Article in Radiology advances, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Sherry S HuangResearch and Scientific Affairs, GE HealthCare, Rochester, MN, 55901, United States.ORCID https://orcid.org/0000-0003-0614-6628
Xinzeng WangMR Clinical Solutions & Research Collaborations, GE HealthCare, Houston, TX, 77030, United States.ORCID https://orcid.org/0000-0002-0415-7246
Patricia LanMR Clinical Solutions & Research Collaborations, GE HealthCare, Menlo Park, CA, 94025, United States.ORCID https://orcid.org/0000-0003-1763-9540
Milica MedvedDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.ORCID https://orcid.org/0000-0003-2945-5511
Nurullah KayaDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.
Clyve K FollanteMR Coils, GE HealthCare, Aurora, OH, 44202, United States.
Yunjeong StickleMR Coils, GE HealthCare, Aurora, OH, 44202, United States.
Jonathan TaylorDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.
Ambereen YousufDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.
Roger EngelmannDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.
Fraser J L RobbMR Clinical Solutions & Research Collaborations, GE HealthCare, Aurora, OH, 44202, United States.
Arnaud GuidonMR Clinical Solutions & Research Collaborations, GE HealthCare, Boston, MA, 02215, United States.
Grace LeeDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.ORCID https://orcid.org/0000-0001-9950-7976
Aytekin OtoDepartment of Radiology, University of Chicago, Chicago, IL, 60637, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: MR diffusion-weighted imaging (DWI), especially at high Purpose: To demonstrate the feasibility of improving DWI quality using a novel 50-channel pelvic coil in conjunction with a deep learning (DL)-based phase correction and a DL-denoising algorithm. Methods: In this prospective, single-center study, 24 consecutive men referred for prostate multiparametric MRI over 16 months were enrolled (age 47-79 years; mean, 68.1 years). Axial T2-weighted images and DWI were obtained using a prototype 50‑channel coil and standard clinical phased array (3 T Architect, GE HealthCare, USA). The DWI acquisitions were reconstructed with the vendor's deep learning denoising algorithm (ARDL). The same raw data were reconstructed offline using an investigational DL Phase Correction algorithm with ARDL (DLPC+ARDL). Two independent readers scored DWI and ADC series using 4 qualitative criteria. SNR and contrast-to-noise ratio (CNR) were measured on Results: Twenty men were analyzable for qualitative and 18 for quantitative metrics (reported as mean ± SD). 50‑channel pelvic coil with DLPC+ARDL produced the highest SNR (99.70 ± 28.50) and CNR (91.68 ± 44.39), exceeding 50‑channel with ARDL alone (SNR 56.44 ± 28.50; CNR 51.11 ± 28.67), 30‑channel anterior array with ARDL (SNR 31.41 ± 13.18; CNR 26.26 ± 13.52), and DLPC + ARDL (SNR 49.4 ± 18.6; CNR 44.7 ± 18.3) (all Conclusion: DWI images acquired using the 50‑channel pelvic coil and reconstructed with the DLPC + ARDL pipeline yield the highest image quality compared to ARDL only pipeline and to all 30-channel coil imaging.

Indexed as

deep-learning denoisingdeep-learning reconstructiondiffusion weighted imagingflexible-coil-arrayphase correctionprostate MRI

Identifiers

PMID42078007
PMCPMC13131225

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.