Evidence map›Paper›PMID 42077488›Full record

ArticleJDS communications2026

Blood adenosine triphosphate luminometry and dynamic viscoelastic coagulometry reference values in healthy newborn dairy calves.

Laura Van Driessche, Gilles Fecteau, Claire Vergneau-Grosset, Sébastien Buczinski

Abstract read
In one paragraph

Article in JDS communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Laura Van DriesscheDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, J2S 2M2.
Gilles FecteauDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, J2S 2M2.
Claire Vergneau-GrossetDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, J2S 2M2.
Sébastien BuczinskiDepartment of Clinical Sciences, Faculty of Veterinary Medicine, Université de Montréal, Saint-Hyacinthe, J2S 2M2.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The primary objective of this study was to determine reference blood values for ATP luminometry and dynamic viscoelastic coagulometry analysis in healthy newborn dairy calves in order to evaluate their potential usefulness for future on-farm detection of sepsis. Secondary methodological objectives were to assess whether ATP luminometry results were influenced by blood collection method, blood matrix (serum, plasma or whole blood), or the addition of a stabilizing solution aimed at minimizing baseline relative light unit (RLU) values. Groups of 21 and 19 healthy calves were included in the study for ATP luminometry and dynamic viscoelastic coagulometry analysis, respectively. We performed ATP measurements using Hygiena AquaSnap Total and AquaSnap Free swabs across the different blood matrices, with and without stabilizing solution. Hemoglobin concentration and hematocrit were measured to account for potential effects of hemolysis and dilution on ATP results. No significant differences in RLU values were observed between sampling methods. Baseline ATP luminometry values were high across all matrices, with median RLU values of 5,062 for serum, 7,198 for plasma, and 7,547 for whole blood, and substantial interindividual variability, particularly for serum and plasma samples. The addition of stabilizing solution did not reduce baseline RLU values, and neither hemoglobin concentration nor hematocrit allowed for meaningful normalization between individuals. In contrast, dynamic viscoelastic coagulometry demonstrated narrow reference ranges and low interindividual variability, with median (interquartile range) values of 172 (154-192) seconds for activated clotting time, 25 (18-34) units/min for clot rate, and 3.30 (2.70-3.90) units for platelet function. Overall, these findings indicated that ATP luminometry, under the conditions evaluated, shows practical and methodological constraints. Conversely, dynamic viscoelastic coagulometry analysis shows promising analytical stability and warrants further investigation in clinically septic calves to determine its potential for early on-farm sepsis detection in newborn dairy calves.

Identifiers

PMID42077488
PMCPMC13131363

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.