Evidence map›Paper›PMID 42076463›Full record

ArticleSensors (Basel, Switzerland)2026

Methodology for Static Pressure Measurement Under Confined Spatial Conditions in the Low-Pressure Range.

Pavla Šabacká, Jiří Maxa, Michal Bílek, Robert Bayer, Tomáš Binar, Petr Bača, Vojtěch Hlavička, Jiří Čupera, Jiří Votava, Vojtěch Kumbár and 1 more

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Pavla ŠabackáFaculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.ORCID 0000-0003-3908-5120
Jiří MaxaFaculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.ORCID 0000-0002-0640-0406
Michal BílekFaculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.
Robert BayerFaculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.ORCID 0000-0002-8528-4430
Tomáš BinarFaculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.ORCID 0000-0003-4426-2857
Petr BačaFaculty of Electrical Engineering and Communication, Brno University of Technology, Technická 10, 616 00 Brno, Czech Republic.ORCID 0000-0001-9793-9767
Vojtěch HlavičkaInstitute of Scientific Instruments of the CAS, Královopolská 147, 612 64 Brno, Czech Republic.ORCID 0009-0006-3963-9364
Jiří ČuperaFaculty of AgriSciences, Mendel University in Brno, Zemědělská 1665/1, 613 00 Brno, Czech Republic.ORCID 0000-0002-3983-7735
Jiří VotavaFaculty of AgriSciences, Mendel University in Brno, Zemědělská 1665/1, 613 00 Brno, Czech Republic.ORCID 0000-0003-3304-9516
Vojtěch KumbárFaculty of AgriSciences, Mendel University in Brno, Zemědělská 1665/1, 613 00 Brno, Czech Republic.ORCID 0000-0003-3987-4613
Lenka DobšákováFaculty of Military Technology, University of Defence, Kounicova 65, 662 10 Brno, Czech Republic.ORCID 0000-0002-7266-6026

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a methodology enabling the use of a Pitot probe for static pressure measurement in supersonic flow under severely confined spatial conditions where standard design guidelines cannot be satisfied. In particular, the recommended placement of a static pressure tapping at a distance of 10-20 tube diameters is not feasible; the proposed approach allows for the tapping to be located immediately downstream of the static tube cone. The methodology combines theoretical analysis, experimental measurements, and Computational Fluid Dynamics (CFD) simulations. Experiments were performed using appropriately selected pressure sensors, while detailed simulations in Ansys Fluent (Ansys 2024 R2) included both a high-fidelity probe model and free-stream flow analysis. By comparing experimental and numerical results, a correction coefficient was established based on the free-stream dynamic pressure obtained from CFD. This enables the accurate estimation of static pressure even in non-ideal probe configurations. The measurement error did not exceed 20%, while in most cases, very good agreement between experimental and CFD results was achieved. The main contribution of this paper is the validated methodology, which extends the applicability of Pitot probes to geometrically constrained environments where conventional static pressure measurement techniques cannot be implemented.

Indexed as

Ansys FluentapertureCFDdifferentially pumped chamberESEMlow-pressurenozzlePitot sensors

Identifiers

PMID42076463
PMCPMC13119809

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.